User's Manual
AUTONOMOUS COUNTER (POWERED TYPE) USER MANUAL [PSM-NGC-P01]
4
⑦ Communication status – Received signal strength indication (RSSI)
Display for 3 seconds during manual communication
(Manual communication: Press the button for 3 seconds in the cumulative shot display mode)
Display status
When communication is successful, the LCD displays as follows.
7. Trouble shooting
① ② ③ ④
① (Error Code): If the communication status is not stable, the communication retries and
communication success / failure status are displayed.
② : Communication failure, Check the communication environment and retry communication.
If you still see communication failure, replace the counter.
③ Communication steps (1~3), Wireless connection steps (1~3)
④ Communication retries (1~2), Wireless connections (1~5)
예) : Communication retry - 1, Communication steps 3 - failure
: Wireless connections - 5, Wireless connection step 1 - failure
Communication failure code and action.
Code
Description
Cause
Action
~
Wireless connection failure
□ System down
□ Unstable wireless comm.
environment
□ System inspection and
improvement.
□ Wireless environment inspection
and improvement
~
Wireless connection failure
and Data transmission
verification failure
□ System down
□ Unstable wireless comm.
□ product defect
□ System inspection and
improvement.
□ Wireless environment inspection
and improvement
□ Product replacement or make
inquiries
Battery status
※ Depending on the operating environment, such as temperature, there may be a temporary change in status.
8. Precautions
① When installing or removing in a hot mold, it may cause burns, so work safely at the proper temperature.
② Replace the counter within 1 month if the battery indicator ( ) is blinking.
③ Temporary communication failure may occur depending on the metal wall or the enclosed environment
causing radio interference, in case of continuous communication failure, check and remove the obstacle.
④ Please note that damages due to non-standard environment, carelessness of the user, or arbitrary operation
cannot be serviced.
Battery indicator
Battery status and action
normal
Low voltage
Under voltage, product replacement
blinking