Falcon® 4400 Series with Windows Mobile® Falcon 4420 48-Key model 26-Key model 52-Key Numbers Up model Product Reference Guide
PSC Inc 959 Terry Street Eugene, Oregon 97402 Telephone: (541) 683-5700 Fax: (541) 345-7140 An Unpublished Work - All rights reserved. No part of the contents of this documentation or the procedures described therein may be reproduced or transmitted in any form or by any means without prior written permission of PSC Inc. or its wholly owned subsidiaries ("PSC").
Table of Contents Preface: About this Guide ..................................................................................... v Chapter 1. Batteries and Power ........................................................................ 1-1 Overview ...................................................................................................................1-1 Suspend Mode ............................................................................................................1-1 Suspending .......
USB Cable ............................................................................................................A-3 Serial Charging Cable ............................................................................................A-4 Printer Cable ........................................................................................................A-4 Serial Printer Adapter ............................................................................................A-4 Holsters and Softcases ........
Supply Voltage .................................................................................................... D-1 USB Cable ................................................................................................................. D-1 Serial Cable ............................................................................................................... D-2 Printer Cable .............................................................................................................
Imager Labels .......................................................................................................... F-45 Other Controls .......................................................................................................... F-45 Appendix G. SDK Installation........................................................................... G-1 About the Software Development Kit (SDK): ............................................................ G-1 Appendix H. Glossary......................
Preface: About this Guide How to Use this Manual This Product Reference Guide contains comprehensive basic user instructions for the Falcon 4400 Series color mobile computer with Windows Mobile®. The manual discusses software, batteries, dock, serial cables, data transfer, as well as advanced user information such as bar code configuration and parameters.
Preface • Appendix A, Accessories, describes Accessories like docks, battery chargers, holsters, and soft cases that are available for the Falcon. • Appendix B, Falcon® Desktop Utility (FDU) allows PSC Windows administrators to configure Windows® Mobile Falcons to control individual user access. • Appendix C, SNMP Interface, describes SNMP (Simple Network Management Protocol) concepts, MIB (Management Information Base) files, and provides additional resources.
Document Conventions NOTES contain information necessary for properly diagnosing, repairing and operating the terminal. The CAUTION symbol advises you of actions that could damage equipment or property. CAUTION A WARNING symbol calls attention to actions that could result in personal injury. WARNING Keystrokes. Filenames, paths, field selections from a drop-down list, and data or keystrokes entered by the user are shown in monospaced typeface. Windows Controls.
Preface Tap and Hold. Tap and hold the stylus to view and select items from a list or drop-down box. Refer to the Falcon 4400 with Windows Mobile® Quick Reference Guide (QRG) for more information on using a stylus with the Falcon. Mouse Actions Applies to the software installation portions of this document using a PC; the Falcon comes equipped with a stylus. Refer to Stylus Actions on page vii, or see the QRG for more information. Click or Select.
Chapter 1 Batteries and Power Overview This section contains the following topics: • Suspend Mode, p. 1-1 • Battery Warnings and Cautions, p. 1-2 • Battery Disposal, p. 1-4. Suspend Mode The Falcon will go into a suspend or sleep mode when it is idle for a period of time. This duration can be customized using the on-screen Power control panel (refer to Advanced Tab, p. 2-20). Suspend mode works and looks just like you have turned the unit off. Press to suspend (put to sleep) the Falcon.
Batteries and Power Resuming Use one of the following methods to resume (wake up the Falcon): • Press to resume (wake up). • Put the Falcon into a dock. • Press the Scan Trigger to wake up the unit (handled version only). When a battery pack is fully discharged while the unit is in suspend mode, the Falcon remains in the suspended mode until the battery pack is charged or external power is supplied via the dock or a power cable.
Battery Warnings and Cautions Always charge the battery at 32°–113°F (0°–45°C) temperature range. If you remove the battery pack or it becomes completely discharged, there is a 30 minute window in which to insert a charged battery pack before the backup battery fails. If your backup battery completely discharges, the contents of the RAM CAUTION memory will be lost. If your back-up battery is less than fully charged, there is a proportionally smaller window of time available.
Batteries and Power Battery Disposal If you must dispose of a battery pack, please follow the CAUTIONS below: CAUTION Use only a battery pack supplied by a PSC reseller for this device.The use of other battery supplies can damage the Falcon and void your warranty. Contact your reseller for the correct power supplies; view your options under Battery Pack, p. A-2 or the PSC price book at www.psc.com.
Chapter 2 Configuration Settings Overview This section describes how to access and configure customized PSC settings and configuration screens. For information about Microsoft configuration items, reference the help system on your device. Access the items on the Settings screen to configure the Falcon. These include date and time, display backlight, volume/sounds, scanner, and power. The first screen you see on your Falcon after powerup is the Today screen. Tap the (Start) icon to access the Start Menu.
Configuration Settings Settings Access the Settings screen from (Start), then tap the desired icon to open the control panel for that item. The icons available on your screen may vary, depending on your initial configuration. There are three types of Settings: • Personal Settings on this page • System Settings on page 2-3 • Connections on page 2-21 This manual describes customized PSC settings and configuration screens.
Settings System Settings PSC System Settings are discussed in this section. For information on Microsoft settings, see the help system on your device. PSC System Settings Backlight, p. 2-4 Decoding, p. 2-5 Falcon Config, p. 2-12 Falcon Information, p. 2-12 Imager, p. 2-13 Keyboard, p. 2-18 Power, p.
Configuration Settings Backlight Increasing backlight brightness can cause the battery pack to discharge at a faster rate. The battery discharge rate decreases with a decrease in backlight usage. Change the Backlight settings by completing the following steps: 1. Tap > Settings > System and tap the Backlight icon. Some Falcon keypads also provide keyboard shortcuts to launch the Backlight control panel: • On the 26-key model press: + ( ). • On the 48-key model press: + ( ).
Settings Figure 2-2. Backlight Settings Using Auto-on while running from battery power will cause the battery pack to discharge at a faster rate. The battery discharge rate decreases with a decrease in backlight usage. 4. Exit and save your modifications by tapping OK, or press on the keypad. Decoding You can configure the Falcon’s decoding options by tapping > Settings > System > Decoding.
Configuration Settings Figure 2-3. Decoding Properties: Audio Select Configure > General from the menu to view other configuration options. • Audio: Sets volume, tone, duration, and number of various types of beeps. Figure 2-4. Decoding Properties: General Options Select Configure > General from the menu to view other configuration options. • General Options: Select from Label Programming Enable, Symbology IDs, Label Prefix, Label Suffix, and Data Separator.
Settings Figure 2-5. Decoding Properties: Decoding Options Select Configure > General from the menu to view other configuration options • Decoding Options: Set the User ID character associated with a symbology, the Redundancy and select Aggressive Decoding when available. Figure 2-6.
Configuration Settings Figure 2-7. Decoding Properties: Imager Options Select Configure > General from the menu to view other configuration options. • Imager Options: (Models with Imaging module only). Enable/Disable Illumination and the Aiming Beam for Imaging Mode lets you select between Concurrent (the aiming beam and the illumination beam turn on at once); and Interlaced (the aimer beam and illumination alternate being on). Set Imager Brightness and Timeout properties using the sliders. Figure 2-8.
Settings • Devices: Enable the keyboard wedge for Bar Code scanner, Magnetic Stripe reader, RFID (if installed), and Read-Ahead options for attached devices. Bar Code Symbology Pages Use the drop-down menus from Configure > 1D Bar Code or 2D Bar Code, or tap the left and right arrow keys to navigate the different pages of the bar code symbology pages. Each bar code symbology opens to its own page, as shown in Figure 2-10 on page 2-10. Figure 2-9.
Configuration Settings Figure 2-10. Common Symbologies: Code 39 and UPC-A • Code 39: Select Enable, Min/Max Lengths, Enable Checksum, Send Checksum, Full ASCII Conversion, and Concatenate. • UPC-A: Select Enable, Send Check Digit, Send System Digit, and Convert to EAN-13.
Settings Refer to Figure 2-10 for an example of the types of fields and options you can modify. Other decoding parameters are described in Programming Parameters, starting on page E-1; bar code settings are provided in Programming Bar Codes, starting on page F-1. OCR The OCR page gives you the following options: • Specify a font by selecting from the drop-down menu. • Select the desired Check Digit from the drop-down menu. See "OCR Configuration" starting on page E-37 for more information.
Configuration Settings Decoding Settings Select from the Decoding Properties Settings menu to restore previous configurations and/or other available default settings. Choose from: • Factory Defaults • Minimum Settings • Maximum Settings • Save (New Settings) • Revert to Saved Settings The settings are saved when you tap OK.
Settings Figure 2-11. Serial Number Locations AVOID EXP OSURE — LASER LIGHT IS EMITTED FROM THIS APERTURE PSC 959 Terry St. PRODUCT OF USA Eugene, OR 97402 Complies with 21CFR and Part 15 of FCC rules. Item # 345-4201-005 DATE OF MANUF RADIO: BREEZECOM EUR: CE0560 CAN: 24611032079A FCC: M52PCRNZZ-00 Serial Number BACKUP BATTERY: 3.
Configuration Settings Figure 2-12. Image Capture Settings A B 3. An hourglass will appear, indicating the image capture process has begun (see Figure 2-12B). Continue to hold the Falcon steady until you hear the capture sound, signifying that the image capture is complete. 4. A File Save message showing the image file name will appear, unless that option has been previously deselected in the File settings (in that case, the file will automatically save without prompting). See Image File, p.
Settings Image File 1. Specify where you want images to be saved in the File Folder field. If you do not select a folder, images will be saved to the default folder “\Images.” Use the … button to browse to a different folder. 2. Use File Format to select the image format you want. You can choose between the following graphics formats: • TIFF (1-bit monochrome) • TIFF (8-bit grayscale) • JPEG (8-bit grayscale) • BMP (1-bit monochrome) • BMP (8-bit grayscale) 3.
Configuration Settings Image Size On the Size tab, modify the image property settings. 1. Tap the Width and Height controls to adjust the image, or enter a value using the on-screen keyboard or the Falcon’s keypad. • Width can be as much as 640 pixels. • Height can be as much as 480 pixels. Reducing the height and width results in cropping of the image to the center. 2. Use Scale to scale the image. Scaling changes the x,y dimensions of the image.
Settings Image Settings 1. JPEG Quality sets the desired quality when the JPEG image format is selected. Selecting a higher quality results in a higher quality image, but a larger file. 2. Brightness provides you with options for the brightness level the imager will use when taking images. 3. Edge Sharpness specifies how much the imager will attempt to sharpen edges in images it takes. Selecting the highest position on the slider gives the sharpest edges, but also increases noise in the image. 4.
Configuration Settings Condition Low light Printed Text Signature Item Recommended Setting Illumination On Brightness 100% Gamma Correction 20 Illumination On Sharpness 100% File format 8-bit Illumination On Sharpness 100% File format 1-bit Keyboard Depending upon which keypad your Falcon has, you will see a different keyboard control panel as shown below. 26-Key Keypad 1. Tap > Settings > System > Keyboard to open the Keyboard control panel. 2.
Settings 48, 52, 5250 and 52-Key Numbers Up Keypads The control panel for the 48, 52, 5250 and 52-key Numbers Up (NU) keypads has some additional options and an additional tab for key mapping. 1. Tap panel. > Settings > System > Keyboard to open the Keyboard control 2. On the Options tab, adjust the slider for Initial Delay. This configures the time to hold down a key before it repeats. Figure 2-13. 48, 52, 5250 and 52-Key Control Panels 3. You can also adjust the slider for Repeat Rate.
Configuration Settings Power Tap > Settings > System > Power to adjust power management settings. Use this control panel to check the charge on the battery or to change the Power settings. Battery Tab The Battery tab provides power indicators for Main battery and Backup battery as shown in Figure 2-14. Save your settings by tapping OK, or press on the keypad.
Settings Connections In the Connections screen you can view or change Internet, intranet and network settings. See the help system on your device for more information. Bluetooth® Device Properties The Bluetooth Device Properties icon will only be visible if Bluetooth hardware has been installed on the unit. This control allows you to enable and disable your device’s Bluetooth interface. It allows selecting a Bluetooth device to connect with and allows for assignment of COM ports.
Configuration Settings Mode tab 1. Select the checkbox forTurn on Bluetooth to enable Bluetooth on the device. 2. Select “Make this device visible to other devices” to allow other devices to discover and view this device. Devices tab 1. Select the Devices tab to display available devices. If there are devices that you have previously connected to, they will already be listed.
Settings 2. Tap a device to display and modify the settings. Tap Save to keep the modifications. 3. To search for new devices, tap on Add new device. The Falcon will search for Bluetooth Devices within range.
Configuration Settings 4. Once scanning is complete, available Bluetooth Device Profiles will be displayed. 5. Select a device to connect, and tap Next.
Settings 6. Enter a password, if needed to connect to the device. 7. Click Yes or No to whether you want to add the selected device to your device list.
Configuration Settings 8. The settings will be displayed. Click Finish to close the dialog. The screen will display the settings for the selected device. COM Ports tab Tap the COM Ports tab to create a new outgoing or incoming port. Tap and hold an existing port to view or edit settings.
Chapter 3 Software Programs Overview "Programs" starting on page 3-1 "Installing Programs" starting on page 3-2 Firmware Update Utility: • Retrieving a Firmware Image Update, p. 3-3. • Installing FUU on the Host PC, p. 3-4. • Updating the Falcon Firmware, p. 3-4. "AutoStart" starting on page 3-6 Programs The Falcon comes with a number of factory-installed programs. To open them, tap > Programs to open the Programs screen, then tap the icon for the program you wish to open.
Software Programs Figure 3-1. Programs screen Installing Programs In order to install a program, your Falcon must be connected to a PC. See the Falcon 4400 QRG for instructions on getting connected. Then, follow the installation instructions for the program you want to install. Once the software is installed on your desktop computer, the installer will transfer the software to your Falcon.
Firmware Update Utility Firmware Update Utility The Falcon is equipped with a field-upgradeable firmware mechanism. Firmware updates for the Falcon can be found on the PSC website (www.psc.com). After you have downloaded the desired update to your PC, there are several ways you can update the firmware on the Falcon. • Use the Falcon Management Utility (FMU) if you have multiple Falcons to update. Refer to the FMU User’s Guide for more information.
Software Programs Installing FUU on the Host PC The Firmware Update Utility (FUU) provides administrators with a field upgrade mechanism. You must have Microsoft® ActiveSync already loaded and running on the host PC to use FUU. Refer to the help system on your device for more information about ActiveSync. Prior to installing FUU, you must remove any previous versions of FUU installed on the host PC. Install PSC’s Falcon® Firmware Update Utility on your PC by completing the following steps: 1.
Firmware Update Utility 4. Select the current *.fpk file and click the Open button. 5. Verify that the Falcon is turned on. Insert the device into a powered dock connected to the host computer. 6. Click the Update Terminal button on the FUU utility on the host PC. 7. FUU will compare the selected firmware image with the firmware already loaded on the Falcon; if the images are different, FUU will proceed to update the firmware image on your Falcon.
Software Programs Please be patient and do not remove the Falcon from the Dock until the procedure is complete. The firmware image of the Falcon can take as long as: • 3 minutes to download using a USB connection. • 22 minutes to download using a serial connection with 115K baud rate. • 130 minutes to download using a serial connection with 19.2K baud rate. 8. After the firmware of your Falcon has been updated, the Falcon will prompt you for input. Follow the on-screen instructions.
AutoStart < Autostart option(s)> Sample: - \windows\pword.exe \file.doc Table 2 breaks down the sample Autostart.ini line. Table 2. Autostart.ini line formatting Autostart option(s) - Full path to executable \windows\pword.exe Command line arguments \file.doc Spaces must be placed between each component of the line in the Autostart.ini.
Software Programs Comments Description Character Query: Request user confirmation ‘?’ when running the executable. Execute only on Cold Reset ‘!’ This will halt parsing the Autostart.ini until the confirmation is answered. This is intended for debugging the Autostart.ini file. None. Cold Reset Only: This will cause the line to execute only after a Cold Reset. An empty line will be treated as a comment line.
AutoStart AutoStart Execute Query Table 4. AutoStart Query options Field Line Number Exe Args Description This is the line number in the script being executed. The executable as parsed by AutoStart. The argument as parsed by AutoStart. The fields may be broken up into multiple lines (as shown in the example) due to limited space in the dialog. Parentheses are used to surround the given field and make it very clear what the value of the field is. Table 5 describes the results of each choice: Table 5.
Software Programs Table 6. Sample Autostart.ini lines Line Description ? \windows\wceload.exe “\My This will confirm the execution of Documents\FDU.cab” \Windows\wceload.exe with specified argument “\My Documents\FDU.cab” \Program Files\App.exe (invalid) This will execute \Program with the argument Files\App.exe. \Program Files\App.exe /run (invalid) This will execute \Program with the argument Files\App.exe /run. “\Program Files\App.exe” / This will execute the program \Program run Files\App.
Appendix A Accessories Overview This appendix covers the following topics: • "Power Supplies" on page A-2. • "Battery Pack" on page A-2. • "Single-Slot Dock" on page A-2. • "Four-Slot Dock" on page A-3. • "Battery Charger" on page A-3. • "Serial Charging Cable" on page A-4. • "USB Cable" on page A-3. • "Printer Cable" on page A-4. • "Serial Printer Adapter" on page A-4 • "Holsters and Softcases" starting on page A-6. • "Holsters" starting on page A-6. • "Softcases" starting on page A-7.
Accessories Power Supplies Use only the correct battery chargers and docks with this Windows Mobile Falcon. The technology used for these models is incompatible with other PSC Falcon chargers and docks. Battery Pack Figure A-1. Battery Pack Single-Slot Dock Figure A-2.
Power Supplies Four-Slot Dock Figure A-3. Four-Slot Dock Battery Charger Figure A-4. Four-Slot Battery Charger USB Cable See "Cable & Connector Configurations" on page D-1.
Accessories Serial Charging Cable See "Cable & Connector Configurations" on page D-1. Printer Cable See "Cable & Connector Configurations" on page D-1. Serial Printer Adapter The Serial Printer Adapter attaches to the bottom of a Falcon unit and allows you to print directly to a printer. Figure A-5. Serial Printer Adapter To attach the printer adapter to a Falcon, you must remove the strap studs, as well as the optional strap stud bumpers, if present. Use the procedure that follows.
Power Supplies Removing Strap Studs/Bumpers Figure A-6. Strap Studs Strap Stud Bumpers Strap Studs 1. Loosen and pull off the strap stud bumpers (if present). If necessary, pry off using a screwdriver. 2. Use a 5/64” Allen wrench (included with the printer adapter) to loosen and remove each Strap Stud. Once you have removed the strap studs, attach the adapter to the Falcon by tightening the thumbscrews on the adapter. Figure A-7.
Accessories Holsters and Softcases A holster and a softcase are available that will work with both the Falcon 4410 and the handled Falcon 4420 models. Holsters Figure A-8.
Holsters and Softcases Softcases Figure A-9.
Accessories Installing the Handle or Handstrap The Falcon 4420 comes from the factory with the handle installed. The Falcon 4410 comes with a handstrap. These can be exchanged with a change-out kit. The handle is removable and can be replaced with a handstrap. When you replace the handle with the handstrap, you lose the ability to press the trigger on the handle and must use the key on the Falcon keypad instead. The key is not available on models with the 48-key keypad.
Installing the Handle or Handstrap Figure A-10. Removing/Replacing a Handstrap Retaining Pin Cover Plate Handstrap Cover Plate Handstrap PDT Retaining Pin is threaded through loop in strap and seated in sockets 3. Replace the screws located just above the battery cover’s latch dials. 4. Connect the handstrap hook onto one of the strap studs at the base of the Falcon. 5. The process is complete upon successful test of the scanning function.
Accessories Figure A-11. Removing/Replacing the Handle Handle PDT 2. Insert the top tab of the handle into the slot at the top of the handle recess (refer to Figure A-11). 3. Replace the screws located just above the battery cover’s latch dials. 4. The process is complete upon successful test of the trigger function.
Tethered Stylus Tethered Stylus An optional Tethered Stylus is available for use on any of the Falcon 4400 series models. The Tether attaches the stylus to the Falcon unit, preventing the stylus from accidentally being lost or misplaced. Tether Installing a Tethered Stylus If your Falcon did not come with a Tethered Stylus, it can be easily installed. Install a Tethered Stylus on the Falcon 44xx as follows: 1. Turn the Falcon face-down. Ensure that power is OFF. 2.
Accessories Figure A-12. Installing/Removing a Tethered Stylus Tether Screw Removing a Tethered Stylus If you want to remove the Tether from your Falcon 44xx, complete the following steps: 1. Turn the Falcon face down. Ensure that power is OFF. 2. Using a Phillips screwdriver, remove the 16 mm screw at the bottom of the Stylus holder that attaches the Tether to the PDT. 3. Use the shorter 6 mm screw included with your Falcon to reattach the Stylus Holder to the Falcon.
Appendix B Falcon® Desktop Utility Overview Falcon® Desktop Utility (FDU) allows PSC Falcon® Windows® administrators to configure Falcon Windows® Mobile Falcons to control individual user access. This includes: • Prevent users from changing Falcon OS settings. • Define keys to access specific functionality/programs. • Restrict which applications can be executed on the terminal. • Internet Explorer access restriction, configuration and customized recovery mechanisms.
Falcon® Desktop Utility Falcon Desktop Utility Getting Started Before you begin, your Falcon must be connected to your PC. See the Falcon 4400 QRG for information on how to connect your Falcon. After you are connected, you must install FDU. Installation The installer for FDU will automatically launch the Application Manager associated with ActiveSync if the "Install FDU via ActiveSync when finished" checkbox was checked during the installation.
Falcon Desktop Utility 5. Specify the destination folder for this installation, or accept the default and click Next. 6. Specify the group name or use the default, then click Next, then Next again to install the files on your PC. 7. Check the “Install FDU via ActiveSync when finished” checkbox, then click Finish. ActiveSync will launch automatically and display a dialog directing to you to follow instructions on your Falcon to finish the installation. 8.
Falcon® Desktop Utility 5. Specify the group name or use the default, then click Next, then Next again to install the files on your PC. 6. Ensure the “Install FDU via ActiveSync when finished” checkbox is not checked, then click Finish. 7. In FMU, create a package for the FDU_WM.cab file, add this file to the package, and specify any convenient installation path on your Falcon. 8. Add this new package to your group. 9. Update your Falcon or group of Falcons to transfer the FDU_WM.cab file to your Falcon..
Falcon Desktop Utility FMU Access the FMU (Falcon Management Utility) from the FMU tab. Figure B-2. FMU Client Tab Fields See the FMU User’s Guide (included on your PSC Product CD) for complete information about setting up and using FMU. Administrative Options (Admin Tab) Tap > Settings > System > Falcon Config to open the Administrative Options control panel.
Falcon® Desktop Utility Figure B-3. Setting a Password/Admin Tab Fields Table B-2. Setting a Password/ Admin Tab Fields Command Enable Falcon Desktop Description Tap this checkbox to activate the FDU functions such as Hot Key assignments, IE Restrictions, Windows Settings, and the authorized application menu. Enter Password Enter a password in the text box. This allows the user to specify a password when this utility is launched. By default there is no password.
Falcon Desktop Utility Setting a Password Set a password as follows: 1. Enter a password in the field. This allows the user to specify a password when this utility is launched. By default there is no password set. Be sure to record the Password for future reference. 2. Re-enter the password in the second field. 3. Tap Set Password to enable the password. 4. Tap OK close Set Password Confirmation. You must tap Set Password prior to exiting FDU in order to store and activate your new password.
Falcon® Desktop Utility This dialog box will only open if a password was defined. Figure B-4. Setting a Password Table B-3. Setting a Password Command Description Enter Password Enter your password using the keypad, or using the stylus on the soft input panel (SIP) in the text box. OK Tap the OK button to accept the password. X Select/tap the X button to cancel the specified Hot Key. Complete the Falcon Config Admin dialog: 1.
Falcon Desktop Utility Setting Hot Keys You can use the Hot Keys (HKeys) tab to associate specific keys, such as , with specific applications. You can also create new Hot Key combinations (see "Adding a New Hot Key" on page B-10). Select the HKeys tab to access these options. New and Delete options for Hot Keys are only available on the Falcon 4400 Series units. For example, you could set to launch a sample application like: \Windows\pword.exe. Figure B-5. Hot Keys Tab Table B-4.
Falcon® Desktop Utility Command Action Description Specify an action to associate with a Hot Key. This list includes: Toggle Taskbar, FDU Admin, and Application Switcher. This option is only available when Action is selected in the Associated Function drop-down list. The is the key initially assigned to FDU Admin. If you wish to assign this key to a different function, you must first select an unassigned Hot Key and assign it to the Action - FDU Admin.
Falcon Desktop Utility Figure B-6. Add a New Hot Key Dialog Note Table B-6. Adding a New Hot Key Dialog Command Description Enter Key Enter the desired key combination in this text box to define a Hot Key. OK Tap the OK button to add the specified Hot Key. X Tap the X button to cancel the specified Hot Key. You cannot add a Hot Key that is already defined. If you attempt to do so, you will receive an error message. 3. Tap OK to save the New Hot Key. If you tap X, the key will not be saved.
Falcon® Desktop Utility Internet Explorer Configuration Tap the IE (Internet Explorer) tab to access the IE Configuration option. Use the IE Error Redirection option to provide customized recovery from common IE errors. When an error occurs, the browser can redirect access to a specified error page with instructions on how to recover from the problem. Figure B-7. IE Configuration Tab / IE Window Features IE Address Bar Refresh Table B-7.
Falcon Desktop Utility Command Description Enable Address Bar Enable/disable visibility of the IE address bar. Warn when leaving Check to receive a security warning when you leave a secure web a secure page page. Warn when security Check to receive a warning when security blocks a web page. blocks page Enable cookies Select whether to allow cookies to be saved on your device. Modifying Windows Controls Tap the Win (Windows Controls) tab to access the Windows Controls option.
Falcon® Desktop Utility Table B-8. Win Tab Fields Command Description Show Taskbar Tap Show Taskbar to specify that the taskbar is shown or hidden. Taskbar Enabled Tap Taskbar Enabled to specify whether the taskbar is accessible. This option is only available when the Show Taskbar is checked. Application Selector Setup Use the Application Selector (AppSelect tab) function to edit, add, or delete applications for the application selector. Figure B-9. AppSelect Tab Table B-9.
Application Selector Setup Command Description Edit Tap Edit to edit the selected entry. Delete Tap Delete to delete the selected entry. Up/Down Tap Up/Down to move an entry up or down in the listview. Add Application Add Application opens when you tap either New or Edit. From Add Application, the administrator can configure and add or change a new application entry in the list. Applications with Run Application at Startup enabled will start automatically when the Application Selector starts up.
Falcon® Desktop Utility Command Description Arguments Enter any command line arguments to be used when an application is executed. Icon File Displays the path/link to the desired icon file. Browse Button Tap to browse for the desired icon file. Run Application at Tap to force this application to auto start when the Application Selector starts up. Applications will be started in the order listed in the authoStartup rized application list. Delay Enter a delay duration in seconds in the combo box.
Application Switcher User Interface Application Switcher User Interface The application switcher provides the same functionality as the standard Windows® Alt+Tab function. This allows the user to cycle through the various open applications. The key can be used to close the Application Switcher. The application switcher is activated via an assigned Action key specified in the Hot Key tab. (Refer to "Setting Hot Keys" on page B-9.
Falcon® Desktop Utility NOTES B-18 Falcon® 4400 Series with Windows Mobile®
Appendix C SNMP Interface Overview SNMP SNMP (Simple Network Management Protocol) is the standard protocol for managing devices on a network. The Falcon Management Utility (FMU) makes use of SNMP to send and receive configuration information to the PSC terminals. Since the networked terminals are constantly running SNMP, this allows FMU to interface with the terminal at any time, without requiring user intervention on the terminal.
SNMP Interface SNMP Concepts Simple Network Management Protocol (SNMP) is a standardized protocol for network management services using a client/server model. The network management program (client) issues queries and commands to the remote device (agent/server). The protocol itself defines a number of variable types and structures, and the rules for using them for data transfer. Using these variable types and rules, there are a number of standard variables that are supported by all SNMP agents.
Overview For example, if the PSC MIB is loaded into OpenView, the administrator can then view all of the values defined by PSC using the names assigned by PSC, as well as a brief explanation of what each value represents. This will also allow the administrator to update most values, and provides range checking information for the tool to take advantage of. The current PSC MIB can be found on the PSC website at www.psc.com in the Downloads area.
SNMP Interface NOTES C-4 Falcon® 4400 Series with Windows Mobile®
Appendix D Cable & Connector Configurations Introduction The following pages contain information about standard interface cables for use in interconnecting the Dock to power and/or peripheral devices. General Specifications Wire Requirements • Cable length should not exceed 15 feet. • Wire gauge = Standard for RJ-45 connectors (28-26 AWG). Supply Voltage Current power supply voltage = 12V, 2.5 amp.
Cable & Connector Configurations Serial Cable Figure D-2 illustrates the connector configuration of the Serial cable for the Falcon. Figure D-2. Serial Connector Configurations HRS 72 inches +/- 2 Falcon End PC End Printer Cable Figure D-3 illustrates the connector configuration of the Printer cable for the Falcon. Figure D-3.
Appendix E Programming Parameters Overview This section contains information about programmable settings for the Falcon 4400 Windows Mobile Falcon. Use the Falcon Management Utility (FMU), the Scanner Control Panel applet, the Imaging or OCR Control Panel applets, or the bar codes provided in Appendix F to program the Falcon. Table E-2 starting on page E-3 provides the following information: • Code Parameter is the “human” name for the programming option. • I.D.
Programming Parameters • Scanner Type shows, with a checkmark, which modules support the specified parameter. Programming Codes Without Parameters The following table describes the functions of special bar codes that take no parameters: Table E-1. Programming Codes Without Parameters Code Parameter Function FF39 Turns every On/Off parameter off and sets all minimum and Maximum Label Lengths to the lowest values.
Bar Code Parameters Bar Code Parameters The following table lists the standard customer programmable settings for the Falcon. Table E-2. Programmable Standard Bar Code Settings Defaults Code Parameter/ Description I. D. # Acceptable Input Codabar Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the Codabar symbology.
Programming Parameters Defaults I. D. # Acceptable Input Send Start/ Stop Instructs the decoder to transmit the decoded start and stop characters of Codabar labels. The start and stop characters will both be translated as A, B, C, or D. 0 3 0 5 Convert to CLSI Restricts the Codabar decoder to only read labels that conforms to CLSI specifications. Label length must be 14, and the data is split into fields of 1, 4, 5, and 4 characters separated by spaces.
Bar Code Parameters Defaults Code Parameter/ Description User ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. I. D. # Acceptable Input 0 3 2 3 Any single ASCII character (00 = Off) Code 39 Scanner Type Min Max Factory Laser/ Linear Imager 2D Imag er 'I' 'I' 'I' 9 9 9 Enter 1 for On and 0 for Off.
Programming Parameters Defaults I. D. # Acceptable Input Concatenate Allows the decoder to retain and join together a series of specially formatted labels, and then send a single transmission of the entire result. 0 1 0 4 Minimum Label Length Set the minimum label length to be less than or equal to maximum label length.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Code 93 Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the Code 93 symbology. 0 4 0 0 On or Off Off On Off 9 Enable Aggressive Decoding Enables more aggressive decoding algorithms to be used in order to scan hard to read labels.
Programming Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Code 128 Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the Code 128 symbology. 0 4 0 8 On or Off Off On On 9 Enable Aggressive Decoding Enables more aggressive decoding algorithms to be used in order to scan hard to read labels.
Bar Code Parameters Defaults Code Parameter/ Description Read Verification Sets the number of times a label must be read before it is transmitted. User ID Specifies the symbology identifier (if any) sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Scanner Type I. D.
Programming Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Scanner Type Min Max Factory Laser/ Linear Imager Convert EAN-13 to ISBN This instructs the decoder to identify ISBN labels and append the check digit (per ISBN guidelines) to the end of the label. 0 5 1 4 On or Off Off Off Off 9 Convert EAN-13 to ISSN This instructs the decoder to identify ISSN labels and append the check digit (per ISSN guidelines) to the end of the label.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input European Article Numbering8 (EAN-8) Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the EAN-8 symbology. 0 5 1 8 On or Off Off On On 9 Enable Aggressive Decoding Enables more aggressive decoding algorithms to be used in order to scan hard to read labels.
Programming Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Interleaved 2 of 5 Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the Interleaved 2 of 5 symbology. 0 2 1 0 On or Off Off On On 9 Enable Aggressive Decoding Enables more aggressive decoding algorithms to be used in order to scan hard to read labels.
Bar Code Parameters Defaults Scanner Type I. D. # Acceptable Input Min Max Factory Laser/ Linear Imager 2D Imag er Maximum Label Length This feature specifies the maximum allowable length of a Interleaved 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. 0 2 2 9 02 - 50 02 50 10 9 9 Read Verification Sets the number of times a label must be read before it is transmitted.
Programming Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Scanner Type Min Max Factory Laser/ Linear Imager 2D Imag er Send Checksum Instructs the terminal to include the checksum in the label transmission. 0 2 0 B On or Off Off Off Off 9 Minimum Label Length Set the minimum label length to be less than or equal to maximum label length.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input MSI Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the MSI symbology. 0 6 0 8 On or Off Off On Off 9 Enable Aggressive Decoding Enables more aggressive decoding algorithms to be used in order to scan hard to read labels. 0 6 0 9 On or Off Off On Off 9 Require 2 Check Digits An MSCI label must contain 2 check digits.
Programming Parameters Defaults Code Parameter/ Description Read Verification Sets the number of times a label must be read before it is transmitted. User ID Specifies the symbology identifier (if any) that is sent by the decoder when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Scanner Type I. D.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input RSS-14 Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er Enter 1 for On and 0 for Off. RSS-14 Enable Enables/disables the RSS-14 symbology. 0 8 0 0 On or Off Off On On 9 RSS-14 to UCC-EAN 128 Instructs the decoder to transmit the label data as one or more UCC128 labels. The transmission will use the UCC-128 AIM identifier.
Programming Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input RSS Expanded Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er Enter 1 for On and 0 for Off. RSS Expanded Enable Enables/disables the RSS Expanded symbology. 0 8 1 0 On or Off Off On On 9 RSS Expanded to UCCEAN 128 Instructs the decoder to transmit the label data as one or more UCC128 labels. The transmission will use the UCC-128 AIM identifier.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Standard 2 of 5 Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er 9 Enter 1 for On and 0 for Off. Enable Enables/disables the Standard 2 of 5 symbology. 0 2 0 0 On or Off Off On Off 9 Enable Aggressive Decoding Enables more aggressive decoding algorithms to be used in order to scan hard to read labels.
Programming Parameters Defaults Scanner Type I. D. # Acceptable Input Min Max Factory Laser/ Linear Imager 2D Imag er Maximum Label Length This feature specifies the maximum allowable length of a Standard 2 of 5 label. The length includes check and data characters. Maximum Label Length should be greater than or equal to Minimum Label Length. 0 2 2 1 01 - 50 01 50 10 9 9 Read Verification Sets the number of times a label must be read before it is transmitted.
Bar Code Parameters Defaults Code Parameter/ Description User ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology I. D. # Acceptable Input 0 1 2 5 Any single ASCII character (00 = Off) Universal Product Code-A (UPC-A) Scanner Type Min Max Factory Laser/ Linear Imager 2D Imag er 'X' 'X' 'X' 9 9 9 Enter 1 for On and 0 for Off.
Programming Parameters Defaults Code Parameter/ Description Read Verification Sets the number of times a label must be read before it is transmitted. User ID Specifies the symbology identifier (if any) sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Scanner Type I. D.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Scanner Type Min Max Factory Laser/ Linear Imager 2D Imag er 9 Convert UPC-E to UPC-A Instructs the decoder to expand UPC-E labels to their UPC-A equivalents. Any UPC-A parameters will then apply to the result. 0 5 0 C On or Off Off On Off 9 Read Verification Sets the number of times a label must be read before it is transmitted.
Programming Parameters Defaults Code Parameter/ Description I. D. # Acceptable Input Scanner Type Min Max Factory Laser/ Linear Imager 2D Imag er 9 Require Extensions Instructs the decoder to require any enabled UPC/EAN extensions (supplemental labels) to be with a label in order for a scan to be successful.
Bar Code Parameters Defaults Scanner Type I. D. # Accept able Input Min Max Factory Aztec Code Maximum This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. 0 B 2 D 1 - 3750 1 3750 3750 9 Aztec Code User ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3.
Programming Parameters Defaults Code Parameter/ Description Datamatrix User Code ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. I. D. # Accept able Input 0 B 2 3 Any single ASCII character (00 = Off) Composite Scanner Type Laser/ Linear Imager 2D Imag er Min Max Factory ‘V’ ‘V’ ‘V’ 9 Enter 1 for On and 0 for Off.
Bar Code Parameters Defaults Code Parameter/ Description Composite User ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. I. D.
Programming Parameters Defaults Code Parameter/ Description OCR I. D. # Accept able Input Also see "OCR Configuration" on page E-37 Min Max Scanner Type Factory Laser/ Linear Imager 2D Imag er Enter 1 for On and 0 for Off. OCR Font Selects which OCR font (if any) the decoder will be allowed to read with an imager 0 C 2 2 0 (None), 1 (OCRA), 2 (OCRB), 3 (U.S. Currency), 4 (MICR E 13 B) OCR Enable Mod 36 Check Digit Enables use of an OCR Mod 36 check digit in a template.
Bar Code Parameters Defaults Code Parameter/ Description I. D. # Accept able Input Scanner Type Min Max Factory Laser/ Linear Imager 2D Imag er PDF-417 Enable Enables/disables the PDF 417 symbology. 0 A 0 0 On or Off Off On On 9 PDF-417 Minimum Set the minimum bar code label length to be less than or equal to maximum label length. 0 A 2 0 1 - 2710 1 2710 1 9 PDF-417 Maximum This feature specifies the maximum allowable length of a label.
Programming Parameters Defaults Scanner Type I. D. # Accept able Input Min Max Factory MicroPDF417 Maximum This feature specifies the maximum allowable length of a label. The length includes check and data characters, if applicable. Maximum Label Length should be greater than or equal to Minimum Label Length. 0 A 2 5 1 - 366 1 366 366 9 MicroPDF417 User Code ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3.
Bar Code Parameters Defaults Code Parameter/ Description QR Code User ID Specifies the symbology identifier (if any) that is sent when parameter Send Code ID (Index 0025) is set to 3. ASCII code zero (null) is used to indicate that an identifier is not to be sent for the symbology. Product Reference Guide I. D.
Programming Parameters Table E-4. Imaging Controls I. D. # Code Parameter/ Description Imaging Controls Acceptable Input Defaults Min Max Factory Enter 1 for On and 0 for Off. Imager Illuminate Enable Instructs the PDT to illuminate the scanning area (independent of any targeting beam) when using an imager.
Bar Code Parameters Code Parameter/ Description I. D. # Acceptable Input Defaults Min Max Factory 0 C 2 5 0 to 3 (0 to 270 degrees in 90 degree increments) 0 0 0 Imaging Scale Specifies how much the imager is to scale images it takes. It is the percentage of the original image that is used to create the final image. Scales the x,y dimensions of the image.
Programming Parameters Code Parameter/ Description I. D. # Acceptable Input Defaults Min Max Factory JPEG Imaging Quality Specifies the level of quality an imager will use when taking images. Lower levels result in images which have greater levels of lost detail, but have smaller storage requirements and transmit faster. 0 C 2 A 0 to 99 (lower to higher) 50 99 99 Imaging Gamma Correction Specifies the amount of correction the imager applies when taking images.
Bar Code Parameters I. D. # Acceptable Input Enables/disables the Spotting Beam 0 0 0 1 Spotting Beam Timeout Code Parameter/ Description Defaults Min Max Factory On or Off On On On Sets the duration of the spotting beam before it automatically turns off. 0 0 2 3 00 = 0.25 sec. 01 = 0.5 sec. 02 = 1.0 sec. 03 = 1.5 sec. 04 = 2.0 sec. 01 01 01 Release Scan Timeout Sets the duration of the scan before it turns off.
Programming Parameters I. D. # Acceptable Input Indicates a label prefix. 0 0 2 6 Indicates a label suffix. 0 0 2 7 Code Parameter/ Description Label Prefix Label Suffix Defaults Min Max Factory Any single ASCII character (00 = Off) No ne Non e None Any single ASCII character (00 = Off) CR CR CR Table E-6.
OCR Configuration OCR Configuration The Falcon provides limited support for OCR configuration. OCR configuration is performed with a combination of PDT parameters and registry settings. For purposes of configuration, OCR is considered one symbology. Only one font can be active at a time. OCR Data Output OCR data is outputted to the system as though it were bar code data. Characters of the OCR fonts are outputted as printed. Only A-Z, 0-9 are supported. The maximum number of OCR rows is three.
Programming Parameters The list box displays templates, with each list item displayed as a one-line string. • Use the Char Type spin box to select allowable characters. • Use the Number to set length. • Select/deselect the Check Digit checkbox. • Tap the “Add” button to add a new list item that conforms to the three controls above this button. • Tap “Delete” to remove the selected item from the list box. • Tap “Custom” to add a template that does not match a standard. See Table E-7 on page E-39.
OCR Configuration Table E-7.
Programming Parameters Multiple Rows A single template can specify up to three rows. The \N character is used to delineate the start of a new row. Table E-9 gives some examples of multiple row templates. Table E-9.
OCR Configuration Table E-10. Multiple Template Examples Template (HEX) Sample Description or 04 04 04 04 0C 0C 04 04 0A 04 04 04 04 04 04 04 04 A string starting with any 4 digits, followed by any 2 upper case letters, ending with 2 digits. OR A string of any 8 digits. A string of any 2 characters. or 05 05 0A 05 05 05 05 0A 05 05 05 05 05 05 OR A string of any 4 characters. or OR A string of any 6 characters.
Programming Parameters Custom Character Classes A custom character class (CCC) is a string of up to 50 printable characters that is associated with a template variable. When a template variable is specified in a template only characters in the associated CCC string will be allowed in the specified character position. The variable \G is associated with custom character class 1 (CCC1) and the variable \H is associated with custom character class 2 (CCC2). Table E-11 gives some examples of how CCCs are used.
OCR Configuration Modulo 10 Check Digit Modulo 10 allows you to set a check digit for the numbers 0 through 9, with values corresponding to the numbers. The general formula for calculating a Modulo 10 check digit is as follows: (dn + . . . + d3 + d2 + d1 + d0) modulo 10 = 0 Modulo 10 Example 1212121212 (1 + 2 + 1 + 2 + 1 + 2 + 1 + 2 + 1 + 2 + x) modulo 10 = 0 (15 + x) modulo 10 = 0 (15 + 5) modulo 10 = 0 x = 5, so the check digit would be 5. The final string including the check digit would be 12121212125.
Programming Parameters Modulo 36 Example ABCD123 A C B D 1 2 3 (10 + 11 + 12 + 13 + 1 + 2 + 3 + x) modulo 36 = 0 (52 + x) modulo 36 = 0 (52 + 20) modulo 36 = 0 x = 20, so using the value from Table E-12, the check digit would be K. The final string including the check digit would be ABCD123K. Table E-13.
OCR Configuration ASCII Hex ASCII Hex ASCII Hex ASCII Hex ETB 17 7 37 W 57 w 77 CAN 18 8 38 X 58 x 78 EM 19 9 39 Y 59 y 79 SUB 1A : 3A Z 5A z 7A ESC 1B ; 3B [ 5B { 7B FS 1C < 3C \ 5C | 7C GS 1D = 3D ] 5D } 7D RS 1E > 3E ^ 5E ~ 7E US 1F ? 3F _ 5F DEL 7F Product Reference Guide E-45
Programming Parameters NOTES E-46 Falcon® 4400 Series with Windows Mobile®
Appendix F Programming Bar Codes Overview This appendix provides bar codes for common setup parameters for programming the Falcon 44xx. Factory default settings are underlined. To make settings that are not provided in the chapter, you can design custom bar codes or use the Falcon Management Utility (FMU) to program the Falcon. Refer to Configuration Settings, on page 2-1. 1D Symbologies Symbologies and bar code setup parameters included in this appendix are: • "Predefined Defaults" on page F-3.
Programming Bar Codes • • "UPC-E" on page F-28. "UPC/EAN Extensions" on page F-29. 2D Symbologies • • • • • • • • "Aztec Code" starting on page F-30. "DataMatrix" starting on page F-32. "Composite" starting on page F-34. "Maxicode" starting on page F-36. "OCR" on page F-38. "PDF-417" starting on page F-39. "MicroPDF-417" starting on page F-41. "QR Code" starting on page F-43. • "Other Controls" starting on page F-45.
Predefined Defaults Predefined Defaults Minimum Registry * / / F F 3 9 F F 3 F Maximum * / / F F 3 A F F 3 F * * * Restore From Registry / / F F 3 C F F 3 F * / / F F 3 D * * / / F F 3 F * Save To Registry Factory * / / F F 3 B F F 3 F * * Codabar ENABLE O n * / / 0 3 0 0 1 F F 3 E * O f f * / / 0 3 0 0 0 F F 3 E * O f f * / / 0 3 0 1 0 F F 3 E * O f f * / / 0 3 0 2 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 3 0 1 1 F F 3 E * ENABLE CHECKSUM O
Programming Bar Codes CONCATENATE O n * / / 0 3 0 4 1 F F 3 E * O f f * / / 0 3 0 4 0 F F 3 E * SEND START/STOP O n * / / 0 3 0 5 1 F F 3 E * O f f * / / 0 3 0 5 0 F F 3 E * * / / 0 3 0 6 0 F F 3 E * * / / 0 3 0 7 0 F F 3 E * * / / 0 3 2 0 3 0 F F 3 E * * / / 0 3 2 0 4 0 F F 3 E * * / / 0 3 2 0 5 0 F F 3 E * CONVERT TO CLSI O n * / / 0 3 0 6 1 F F 3 E * O f f ALLOW WIDE INTERCHARACTER GAPS O n * / / 0 3 0 7 1 F F 3 E * O f f MINIMUM LENGTH 3 0 1 * / / 0 3
Code 39 MAXIMUM LENGTH 3 0 1 * / / 0 3 2 1 0 1 F F 3 E * 1 0 * / / 0 3 2 1 3 0 F F 3 E * * / / 0 3 2 1 4 0 F F 3 E * * / / 0 3 2 1 5 0 F F 3 E * * / / 0 3 2 2 0 3 F F 3 E * * / / 0 3 2 2 0 4 F F 3 E * 4 0 * / / 0 3 2 1 1 0 F F 3 E * 5 0 2 0 * / / 0 3 2 1 2 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 3 2 2 0 1 F F 3 E * 2 4 * / / 0 3 2 2 0 2 F F 3 E * Code 39 ENABLE O n * / / 0 1 0 0 1 F F 3 E * O f f * / / 0 1 0 0 0 F F 3 E * ENABLE AGGRESSIVE DECODING O
Programming Bar Codes ENABLE CHECKSUM O n * / / 0 1 0 2 1 F F 3 E * O f f * / / 0 1 0 2 0 F F 3 E * * / / 0 1 0 3 0 F F 3 E * * / / 0 1 0 5 0 F F 3 E * * / / 0 1 0 4 0 F F 3 E * SEND CHECKSUM O n * / / 0 1 0 3 1 F F 3 E * O f f FULL ASCII MODE O n * / / 0 1 0 5 1 F F 3 E * O f f CONCATENATE O n * / / 0 1 0 4 1 F F 3 E * O f f MINIMUM LENGTH 1 * / / 0 1 2 0 0 1 F F 3 E * 1 0 * / / 0 1 2 0 3 0 F F 3 E * * / / 0 1 2 0 4 0 F F 3 E * * / / 0 1 2 0 5 0 F F 3
Code 39 MAXIMUM LENGTH 3 0 1 * / / 0 1 2 1 0 1 F F 3 E * 1 0 * / / 0 1 2 1 3 0 F F 3 E * * / / 0 1 2 1 4 0 F F 3 E * * / / 0 1 2 1 5 0 F F 3 E * * / / 0 1 2 2 0 3 F F 3 E * * / / 0 1 2 2 0 4 F F 3 E * 4 0 * / / 0 1 2 1 1 0 F F 3 E * 5 0 2 0 * / / 0 1 2 1 2 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 1 2 2 0 1 F F 3 E * 2 4 * / / 0 1 2 2 0 2 F F 3 E * Product Reference Guide F-7
Programming Bar Codes Code 93 ENABLE O n * / / 0 4 0 0 1 F F 3 E * O f f * / / 0 4 0 0 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 4 0 1 1 F F 3 E * O f f * / / 0 4 0 1 0 F F 3 E * * / / 0 4 2 0 3 0 F F 3 E * * / / 0 4 2 0 4 0 F F 3 E * * / / 0 4 2 0 5 0 F F 3 E * * / / 0 4 2 1 3 0 F F 3 E * * / / 0 4 2 1 4 0 F F 3 E * MINIMUM LENGTH 3 0 2 * 1 0 * / / / / 0 4 2 0 0 2 F F 3 E * 0 4 2 0 1 0 F F 3 E * 2 0 4 0 5 0 * / / 0 4 2 0 2 0 F F 3 E * MAXIMUM
Code 93 2 0 5 0 * / / 0 4 2 1 2 0 F F 3 E * * / / 0 4 2 1 5 0 F F 3 E * * / / 0 4 2 2 0 3 F F 3 E * * / / 0 4 2 2 0 4 F F 3 E * READ VERIFICATION 3 1 * / / 0 4 2 2 0 1 F F 3 E * 2 4 * / / 0 4 2 2 0 2 F F 3 E * Product Reference Guide F-9
Programming Bar Codes Code 128 ENABLE O n * / / 0 4 0 8 1 F F 3 E * O f f * / / 0 4 0 8 0 F F 3 E * O f f * / / 0 4 0 9 0 F F 3 E * * / / 0 4 0 C 0 F F 3 E * * / / 0 4 0 E 0 F F 3 E * * / / 0 4 2 4 3 0 F F 3 E * * / / 0 4 2 4 4 0 F F 3 E * * / / 0 4 2 4 5 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 4 0 9 1 F F 3 E * ENABLE UCC/EAN-128 O n * / / 0 4 0 C 1 F F 3 E * O f f ISBT CONCATENATION O n * / / 0 4 0 E 1 F F 3 E * O f f MINIMUM LENGTH 3 0 1 * /
Code 128 2 0 * / / 0 4 2 4 2 0 F F 3 E * MAXIMUM LENGTH 3 0 1 * / / 0 4 2 5 0 1 F F 3 E * 1 0 * / / 0 4 2 5 3 0 F F 3 E * * / / 0 4 2 5 4 0 F F 3 E * * / / 0 4 2 5 5 0 F F 3 E * * / / 0 4 2 6 0 3 F F 3 E * * / / 0 4 2 6 0 4 F F 3 E * 4 0 * / / 0 4 2 5 1 0 F F 3 E * 5 0 2 0 * / / 0 4 2 5 2 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 4 2 6 0 1 F F 3 E * 2 4 * / / 0 4 2 6 0 2 F F 3 E * Product Reference Guide F-11
Programming Bar Codes EAN-13 ENABLE O n * / / 0 5 1 0 1 F F 3 E * O f f * / / 0 5 1 0 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 5 1 1 1 F F 3 E * O f f * / / 0 5 1 1 0 F F 3 E * SEND CHECK DIGIT O n * / / 0 5 1 2 1 F F 3 E * O f f * / / 0 5 1 2 0 F F 3 E * O f f * / / 0 5 1 3 0 F F 3 E * O f f * / / 0 5 1 4 0 F F 3 E * * / / 0 5 1 5 0 F F 3 E * SEND SYSTEM DIGIT O n * / / 0 5 1 3 1 F F 3 E * CONVERT EAN-13 TO ISBN O n * / / 0 5 1 4 1 F F 3 E * CON
EAN-13 ENABLE EAN 4-DIGIT PRICE/WEIGHT CHECK DIGIT O n * / / 0 5 1 6 1 F F 3 E * O f f * / / 0 5 1 6 0 F F 3 E * ENABLE EAN 5-DIGIT PRICE/WEIGHT CHECK DIGIT O n * / / 0 5 1 7 1 F F 3 E * O f f * / / 0 5 1 7 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 5 2 4 0 1 F F 3 E * 2 * / / 0 5 2 4 0 3 F F 3 E * * / / 0 5 2 6 0 4 F F 3 E * 4 * / / 0 5 2 4 0 2 F F 3 E * Product Reference Guide F-13
Programming Bar Codes EAN-8 ENABLE O n * / / 0 5 1 8 1 F F 3 E * O f f * / / 0 5 1 8 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 5 1 9 1 F F 3 E * O f f * / / 0 5 1 9 0 F F 3 E * SEND CHECK DIGIT O n * / / 0 5 1 A 1 F F 3 E * O f f * / / 0 5 1 A 0 F F 3 E * * / / 0 5 1 B 0 F F 3 E * CONVERT EAN-8 TO EAN-13 O n * / / 0 5 1 B 1 F F 3 E * O f f READ VERIFICATION 3 1 * / / 0 5 2 6 0 1 F F 3 E * 2 / / 0 5 2 6 0 3 F F 3 E * * / / 0 5 2 6 0 4 F F 3 E * 4 *
Interleaved 2 of 5 Interleaved 2 of 5 ENABLE O n * / / 0 2 1 0 1 F F 3 E * O f f * / / 0 2 1 0 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 2 1 1 1 F F 3 E * O f f * / / 0 2 1 1 0 F F 3 E * ENABLE CHECKSUM O n * / / 0 2 1 2 1 F F 3 E * O f f * / / 0 2 1 2 0 F F 3 E * O f f * / / 0 2 1 3 0 F F 3 E * O f f * / / 0 2 1 4 0 F F 3 E * SEND CHECKSUM O n * / / 0 2 1 3 1 F F 3 E * ENABLE CASE CODE O n * / / 0 2 1 4 1 F F 3 E * MINIMUM LENGTH 3 0 2 * / / 0 2 2
Programming Bar Codes 1 0 2 0 * / / 0 2 2 8 1 0 F F 3 E * * / / 0 2 2 8 2 0 F F 3 E * 5 0 * / / 0 2 2 8 5 0 F F 3 E * * / / 0 2 2 9 3 0 F F 3 E * * / / 0 2 2 9 4 0 F F 3 E * * / / 0 2 2 9 5 0 F F 3 E * * / / 0 2 2 A 0 3 F F 3 E * * / / 0 2 2 A 0 4 F F 3 E * MAXIMUM LENGTH 3 0 2 * / / 0 2 2 9 0 2 F F 3 E * 4 0 1 0 * / / 0 2 2 9 1 0 F F 3 E * 2 0 5 0 * / / 0 2 2 9 2 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 2 2 A 0 1 F F 3 E * 2 4 * F-16 / / 0 2 2 A
Matrix 2 of 5 Matrix 2 of 5 ENABLE O n * / / 0 2 0 8 1 F F 3 E * O f f * / / 0 2 0 8 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 2 0 9 0 F F 3 E * O f f * / / 0 2 0 9 1 F F 3 E * ENABLE CHECKSUM O n * / / 0 2 0 A 1 F F 3 E * O f f * / / 0 2 0 A 0 F F 3 E * * / / 0 2 0 B 0 F F 3 E * SEND CHECKSUM O n * / / 0 2 0 B 1 F F 3 E * O f f MINIMUM LENGTH 3 0 1 * / / 0 2 2 4 0 1 F F 3 E * * / / 0 2 2 4 3 0 F F 3 E * * / / 0 2 2 4 4 0 F F 3 E * * / / 0 2 2 4
Programming Bar Codes MAXIMUM LENGTH 3 0 1 * / / 0 2 2 5 0 1 F F 3 E * * / / 0 2 2 5 3 0 F F 3 E * * / / 0 2 2 5 4 0 F F 3 E * * / / 0 2 2 5 5 0 F F 3 E * * / / 0 2 2 6 0 3 F F 3 E * * / / 0 2 2 6 0 4 F F 3 E * 4 0 1 0 * / / 0 2 2 5 1 0 F F 3 E * 2 0 5 0 * / / 0 2 2 5 2 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 2 2 6 0 1 F F 3 E * 2 4 * F-18 / / 0 2 2 6 0 2 F F 3 E * Falcon® 4400 Series with Windows Mobile®
MSI MSI ENABLE O n * / / 0 6 0 8 1 F F 3 E * O f f * / / 0 6 0 8 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 6 0 9 1 F F 3 E * O f f * / / 0 6 0 9 0 F F 3 E * REQUIRE 2 CHECK DIGITS O n * / / 0 6 0 A 1 F F 3 E * O f f * / / 0 6 0 A 0 F F 3 E * O f f * / / 0 6 0 B 0 F F 3 E * O f f * / / 0 6 0 C 0 F F 3 E * SEND CHECK DIGITS O n * / / 0 6 0 B 1 F F 3 E * 2ND CHECK DIGIT MOD 11 O n * / / 0 6 0 C 1 F F 3 E * MINIMUM LENGTH 1 0 1 * / / 0 6 2 4 0 1 F F 3 E
Programming Bar Codes 1 5 7 * / / 0 6 2 4 0 7 F F 3 E * * / / 0 6 2 4 1 5 F F 3 E * * / / 0 6 2 5 1 0 F F 3 E * * / / 0 6 2 5 1 2 F F 3 E * * / / 0 6 2 5 1 5 F F 3 E * * / / 0 6 2 6 0 3 F F 3 E * * / / 0 6 2 6 0 4 F F 3 E * MAXIMUM LENGTH 1 0 1 * / / 0 6 2 5 0 1 F F 3 E * 1 2 4 * / / 0 6 2 5 0 4 F F 3 E * 1 5 7 * / / 0 6 2 5 0 7 F F 3 E * READ VERIFICATION 3 1 * / / 0 6 2 6 0 1 F F 3 E * 2 4 * F-20 / / 0 6 2 6 0 2 F F 3 E * Falcon® 4400 Series with Wi
Pharmacode 39 (Code 32) Pharmacode 39 (Code 32) ENABLE O n * / / 0 1 1 0 1 F F 3 E * O f f * / / 0 1 1 0 0 F F 3 E * O f f * / / 0 1 1 2 0 F F 3 E * O f f * / / 0 1 1 3 0 F F 3 E * * / / 0 8 0 0 0 F F 3 E * * / / 0 8 0 4 0 F F 3 E * SEND CHECKSUM O n * / / 0 1 1 2 1 F F 3 E * SEND START/STOP O n * / / 0 1 1 3 1 F F 3 E * RSS-14 ENABLE O n * / / 0 8 0 0 1 F F 3 E * O f f ENABLE RSS-14 to UCC-128 O n * / / 0 8 0 4 1 F F 3 E * Product Reference Guide O f f F-21
Programming Bar Codes RSS Limited ENABLE O n * / / 0 8 0 8 1 F F 3 E * O f f * / / 0 8 0 8 0 F F 3 E * * / / 0 8 0 C 0 F F 3 E * ENABLE RSS Limited to UCC-128 O n * / / 0 8 0 C 1 F F 3 E * O f f RSS Expanded ENABLE O n * / / 0 8 1 0 1 F F 3 E * O f f * / / 0 8 1 0 0 F F 3 E * * / / 0 8 1 4 0 F F 3 E * ENABLE RSS Expanded to UCC-128 O n * / / 0 8 1 4 1 F F 3 E * O f f MINIMUM LENGTH 4 5 1 * / / 0 8 2 4 0 1 F F 3 E * 1 5 / / 0 8 2 4 4 5 F F 3 E * * / / 0 8 2 4
RSS Expanded 3 0 7 4 * / / 0 8 2 4 3 0 F F 3 E * * / / 0 8 2 4 7 4 F F 3 E * * / / 0 8 2 5 4 5 F F 3 E * * / / 0 8 2 5 6 0 F F 3 E * * / / 0 8 2 5 7 4 F F 3 E * MAXIMUM LENGTH 4 5 1 * / / 0 8 2 5 0 1 F F 3 E * 1 5 6 0 * / / 0 8 2 5 1 5 F F 3 E * 3 0 7 4 * / / 0 8 2 5 3 0 F F 3 E * Product Reference Guide F-23
Programming Bar Codes Standard 2 of 5 ENABLE O n * / / 0 2 0 0 1 F F 3 E * O f f * / / 0 2 0 0 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 2 0 1 1 F F 3 E * O f f * / / 0 2 0 1 0 F F 3 E * ENABLE CHECKSUM O n * / / 0 2 0 2 1 F F 3 E * O f f * / / 0 2 0 2 0 F F 3 E * O f f * / / 0 2 0 3 0 F F 3 E * O f f * SEND CHECKSUM O n * / / 0 2 0 3 1 F F 3 E * USE 2-BAR START/STOP O n * / / 0 2 0 4 1 F F 3 E * / / 0 2 0 4 0 F F 3 E * MINIMUM LENGTH 3 0 1 * / /
Standard 2 of 5 1 0 5 0 * / / 0 2 2 0 1 0 F F 3 E * * / / 0 2 2 0 2 0 F F 3 E * * / / 0 2 2 0 5 0 F F 3 E * * / / 0 2 2 1 3 0 F F 3 E * * / / 0 2 2 1 4 0 F F 3 E * * / / 0 2 2 1 5 0 F F 3 E * * / / 0 2 2 2 0 3 F F 3 E * * / / 0 2 2 2 0 4 F F 3 E * 2 0 MAXIMUM LENGTH 3 0 1 * / / 0 2 2 1 0 1 F F 3 E * 4 0 1 0 * / / 0 2 2 1 1 0 F F 3 E * 2 0 5 0 * / / 0 2 2 1 2 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 2 2 2 0 1 F F 3 E * 2 4 * / / 0 2 2 2 0 2 F F 3 E
Programming Bar Codes Trioptic ENABLE O n * / / 0 1 0 8 1 F F 3 E * O f f * / / 0 1 0 8 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 1 0 9 1 F F 3 E * O f f * / / 0 1 0 9 0 F F 3 E * * / / 0 1 2 4 0 3 F F 3 E * * / / 0 1 2 4 0 4 F F 3 E * * / / 0 5 0 0 0 F F 3 E * O f f * / / 0 5 0 1 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 1 2 4 0 1 F F 3 E * 2 4 * / / 0 1 2 4 0 2 F F 3 E * UPC-A ENABLE O n * / / 0 5 0 0 1 F F 3 E * O f f ENABLE AGGRESSIVE DECODIN
UPC-A SEND CHECK DIGIT O n * / / 0 5 0 2 1 F F 3 E * O f f * / / 0 5 0 2 0 F F 3 E * O f f * / / 0 5 0 3 0 F F 3 E * O f f * / / 0 5 0 4 0 F F 3 E * SEND SYSTEM DIGIT O n * / / 0 5 0 3 1 F F 3 E * CONVERT UPC-A TO EAN-13 O n * / / 0 5 0 4 1 F F 3 E * READ VERIFICATION 3 1 * / / 0 5 2 0 0 1 F F 3 E * 2 * / / 0 5 2 0 0 3 F F 3 E * * / / 0 5 2 0 0 4 F F 3 E * 4 * / / 0 5 2 0 0 2 F F 3 E * Product Reference Guide F-27
Programming Bar Codes UPC-E ENABLE SYSTEM DIGIT 0 O n * / / 0 5 0 8 1 F F 3 E * O f f * / / 0 5 0 8 0 F F 3 E * ENABLE AGGRESSIVE DECODING O n * / / 0 5 0 9 1 F F 3 E * O f f * / / 0 5 0 9 0 F F 3 E * SEND CHECK DIGIT O n * / / 0 5 0 A 1 F F 3 E * O f f * / / 0 5 0 A 0 F F 3 E * O f f * / / 0 5 0 B 0 F F 3 E * O f f * / / 0 5 0 C 0 F F 3 E * SEND SYSTEM DIGIT O n * / / 0 5 0 B 1 F F 3 E * CONVERT UPC-E TO UPC-A O n * / / 0 5 0 C 1 F F 3 E * READ VERIFICATION
UPC/EAN Extensions UPC/EAN Extensions ENABLE 2-DIGIT EXTENSIONS O n * / / 0 5 1 C 1 F F 3 E * O f f * / / 0 5 1 C 0 F F 3 E * ENABLE 5-DIGIT EXTENSIONS O n * / / 0 5 1 D 1 F F 3 E * O f f * / / 0 5 1 D 0 F F 3 E * * / / 0 5 1 E 0 F F 3 E * ENABLE CODE 128 EXTENSIONS O n * / / 0 5 1 E 1 F F 3 E * O f f REQUIRE EXTENSIONS O n * / / 0 5 1 F 1 F F 3 E * O f f * / / 0 5 1 F 0 F F 3 E * READ VERIFICATION 3 1 * / / 0 5 2 8 0 1 F F 3 E * 2 * / / 0 5 2 8 0 3 F F 3 E *
Programming Bar Codes 2D Symbologies Aztec Code ENABLE O n * / / 0 B 1 8 1 F F 3 E * O f f * / / 0 B 1 8 0 F F 3 E * * / / 0 B 1 A 0 F F 3 E * ENABLE AZTEC CODE RUNES O n * / / 0 B 1 A 1 F F 3 E * O f f MINIMUM LENGTH 1 * / / 0 B 2 C 0 1 F F 3 E * * / / 0 B 2 C 7 5 0 F F 3 E * * / / 0 B 2 C 1 5 0 0 F F 3 E * * / / 0 B 2 C 2 2 5 0 F F 3 E * 750 1500 2250 F-30 Falcon® 4400 Series with Windows Mobile®
Aztec Code 3000 * / / 0 B 2 C 3 0 0 0 F F 3 E * * / / 0 B 2 C 3 7 5 0 F F 3 E * * / / 0 B 2 D 0 1 F F 3 E * * / / 0 B 2 D 7 5 0 F F 3 E * * / / 0 B 2 D 1 5 0 0 F F 3 E * * / / 0 B 2 D 2 2 5 0 F F 3 E * * / / 0 B 2 D 3 0 0 0 F F 3 E * * / / 0 B 2 D 3 7 5 0 F F 3 E * 3750 MAXIMUM LENGTH 1 750 1500 2250 3000 3750 Product Reference Guide F-31
Programming Bar Codes DataMatrix ENABLE O n * / / 0 B 0 0 1 F F 3 E * O f f * / / 0 B 0 0 0 F F 3 E * MINIMUM LENGTH 1 * / / 0 B 2 0 0 1 F F 3 E * * / / 0 B 2 0 3 0 0 F F 3 E * * / / 0 B 2 0 6 0 0 F F 3 E * * / / 0 B 2 0 9 0 0 F F 3 E * * / / 0 B 2 0 1 2 0 0 F F 3 E * * / / 0 B 2 0 1 5 0 0 F F 3 E * 300 600 900 1200 1500 F-32 Falcon® 4400 Series with Windows Mobile®
DataMatrix MAXIMUM LENGTH 1 * / / 0 B 2 1 0 1 F F 3 E * * / / 0 B 2 1 3 0 0 F F 3 E * * / / 0 B 2 1 6 0 0 F F 3 E * * / / 0 B 2 1 9 0 0 F F 3 E * * / / 0 B 2 1 1 2 0 0 F F 3 E * * / / 0 B 2 1 1 5 0 0 F F 3 E * 300 600 900 1200 1500 Product Reference Guide F-33
Programming Bar Codes Composite ENABLE O n * / / 0 A 1 0 1 F F 3 E * O f f * / / 0 A 1 0 0 F F 3 E * MINIMUM LENGTH 1 * / / 0 A 2 8 0 1 F F 3 E * * / / 0 A 2 8 5 0 0 F F 3 E * * / / 0 A 2 8 1 0 0 0 F F 3 E * * / / 0 A 2 8 1 5 0 0 F F 3 E * * / / 0 A 2 8 2 0 0 0 F F 3 E * * / / 0 A 2 8 2 4 3 5 F F 3 E * 500 1000 1500 2000 2435 F-34 Falcon® 4400 Series with Windows Mobile®
Composite MAXIMUM LENGTH 1 * / / 0 A 2 9 0 1 F F 3 E * * / / 0 A 2 9 5 0 0 F F 3 E * * / / 0 A 2 9 1 0 0 0 F F 3 E * * / / 0 A 2 9 1 5 0 0 F F 3 E * * / / 0 A 2 9 2 0 0 0 F F 3 E * * / / 0 A 2 9 2 4 3 5 F F 3 E * 500 1000 1500 2000 2435 Product Reference Guide F-35
Programming Bar Codes Maxicode ENABLE O n * / / 0 B 0 8 1 F F 3 E * O f f * / / 0 B 0 8 0 F F 3 E * MINIMUM LENGTH 1 * / / 0 B 2 4 0 1 F F 3 E * * / / 0 B 2 4 2 5 F F 3 E * * / / 0 B 2 4 5 0 F F 3 E * * / / 0 B 2 4 7 5 F F 3 E * * / / 0 B 2 4 1 0 0 F F 3 E * * / / 0 B 2 4 1 3 8 F F 3 E * 25 50 75 100 138 F-36 Falcon® 4400 Series with Windows Mobile®
Maxicode MAXIMUM LENGTH 1 * / / 0 B 2 5 0 1 F F 3 E * * / / 0 B 2 5 2 5 F F 3 E * * / / 0 B 2 5 5 0 F F 3 E * * / / 0 B 2 5 7 5 F F 3 E * * / / 0 B 2 5 1 0 0 F F 3 E * * / / 0 B 2 5 1 3 8 F F 3 E * 25 50 75 100 138 Product Reference Guide F-37
Programming Bar Codes OCR ENABLE O n * / / 0 C 2 2 1 F F 3 E * O f f * / / 0 C 2 2 0 F F 3 E * OCR FONT OCR-A * / / 0 C 2 2 1 F F 3 E * * / / 0 C 2 2 2 F F 3 E * * / / 0 C 2 2 3 F F 3 E * * / / 0 C 2 2 4 F F 3 E * OCR-B MICR US Currency ENABLE OCR CHECK DIGIT On Off * / / 0 C 0 2 1 F F 3 E * * / / 0 C 0 2 0 F F 3 E * * / / 0 C 0 3 0 F F 3 E * ENABLE MOD 36 CHECK DIGIT On Off * F-38 / / 0 C 0 3 1 F F 3 E * Falcon® 4400 Series with Windows Mobile®
PDF-417 PDF-417 ENABLE O n * / / 0 A 0 0 1 F F 3 E * O f f * / / 0 A 0 0 0 F F 3 E * MINIMUM LENGTH 1 * / / 0 A 2 0 0 1 F F 3 E * * / / 0 A 2 0 5 0 0 F F 3 E * * / / 0 A 2 0 1 0 0 0 F F 3 E * * / / 0 A 2 0 1 5 0 0 F F 3 E * * / / 0 A 2 0 2 0 0 0 F F 3 E * * / / 0 A 2 0 2 7 1 0 F F 3 E * 500 1000 1500 2000 2710 Product Reference Guide F-39
Programming Bar Codes MAXIMUM LENGTH 1 * / / 0 A 2 1 0 1 F F 3 E * * / / 0 A 2 1 5 0 0 F F 3 E * * / / 0 A 2 1 1 0 0 0 F F 3 E * * / / 0 A 2 1 1 5 0 0 F F 3 E * * / / 0 A 2 1 2 0 0 0 F F 3 E * * / / 0 A 2 1 2 7 1 0 F F 3 E * 500 1000 1500 2000 2710 F-40 Falcon® 4400 Series with Windows Mobile®
MicroPDF-417 MicroPDF-417 ENABLE O n * / / 0 A 0 8 1 F F 3 E * O f f * / / 0 A 0 8 0 F F 3 E * MINIMUM LENGTH 1 * / / 0 A 2 4 0 1 F F 3 E * * / / 0 A 2 4 7 0 F F 3 E * * / / 0 A 2 4 1 5 0 F F 3 E * 70 150 230 * / / 0 A 2 4 2 3 0 F F 3 E * * / / 0 A 2 4 3 0 0 F F 3 E * * / / 0 A 2 4 3 6 6 F F 3 E * 300 366 Product Reference Guide F-41
Programming Bar Codes MAXIMUM LENGTH 1 * / / 0 A 2 5 0 1 F F 3 E * * / / 0 A 2 5 7 0 F F 3 E * * / / 0 A 2 5 1 5 0 F F 3 E * * / / 0 A 2 5 2 3 0 F F 3 E * * / / 0 A 2 5 3 0 0 F F 3 E * * / / 0 A 2 5 3 6 6 F F 3 E * 70 150 230 300 366 F-42 Falcon® 4400 Series with Windows Mobile®
QR Code QR Code ENABLE O n * / / 0 B 1 0 1 F F 3 E * O f f * / / 0 B 1 0 0 F F 3 E * MINIMUM LENGTH 1 * / / 0 B 2 8 0 1 F F 3 E * * / / 0 B 2 8 7 0 0 F F 3 E * * / / 0 B 2 8 1 4 0 0 F F 3 E * * / / 0 B 2 8 2 1 0 0 F F 3 E * * / / 0 B 2 8 2 8 0 0 F F 3 E * * / / 0 B 2 8 3 5 0 0 F F 3 E * 700 1400 2100 2800 3500 Product Reference Guide F-43
Programming Bar Codes MAXIMUM LENGTH 1 * / / 0 B 2 9 0 1 F F 3 E * * / / 0 B 2 9 7 0 0 F F 3 E * * / / 0 B 2 9 1 4 0 0 F F 3 E * * / / 0 B 2 9 2 1 0 0 F F 3 E * * / / 0 B 2 9 2 8 0 0 F F 3 E * * / / 0 B 2 9 3 5 0 0 F F 3 E * 700 1400 2100 2800 3500 F-44 Falcon® 4400 Series with Windows Mobile®
Imager Labels Imager Labels ILLUMINATION ENABLE O n * / / 0 0 0 8 1 F F 3 E * O f f * / / 0 0 0 8 0 F F 3 E * * / / 0 0 0 9 0 F F 3 E * * / / 0 0 0 A 0 F F 3 E * * / / 0 C 0 8 0 F F 3 E * AIM MODE O n * / / 0 0 0 9 1 F F 3 E * O f f AIM ENABLE O n * / / 0 0 0 A 1 F F 3 E * O f f LED ENABLE O n * / / 0 C 0 8 1 F F 3 E * O f f Other Controls BEEPER VOLUME Off * / / F F 2 0 0 0 F F 3 E * * / / F F 2 0 0 1 F F 3 E * Lowest Product Reference Guide F-45
Programming Bar Codes Medium * / / F F 2 0 0 4 F F 3 E * * / / F F 2 0 0 7 F F 3 E * * / / F F 2 0 0 8 F F 3 E * * / / F F 2 0 0 9 F F 3 E * Highest Higher (Increases the current value one increment higher) Lower (Decreases the current value one increment lower) NUMBER OF GOOD-READ BEEPS 1 * / / 0 0 2 0 0 1 F F 3 E * * / / 0 0 2 0 0 2 F F 3 E * * / / 0 0 2 0 0 3 F F 3 E * * / / 0 0 2 0 0 4 F F 3 E * 2 3 4 F-46 Falcon® 4400 Series with Windows Mobile®
Other Controls GOOD-READ BEEP TONE Lowest * / / 0 0 2 1 0 0 F F 3 E * * / / 0 0 2 1 0 3 F F 3 E * * / / 0 0 2 1 0 7 F F 3 E * Medium Highest GOOD-READ BEEP DURATION (IN SECONDS) 0.07 * / / 0 0 2 2 0 0 F F 3 E * * / / 0 2 2 0 0 1 F F 3 E * * / / 0 0 2 2 0 2 F F 3 E * * / / 0 0 2 2 0 3 F F 3 E * 0.13 0.18 0.
Programming Bar Codes Long Range Trigger Mode Spot Timeout * / / 0 0 0 0 0 F F 3 E * * / / 0 0 0 0 1 F F 3 E * * / / 0 0 0 1 1 F F 3 E * * / / 0 0 0 1 0 F F 3 E * * / / 0 0 2 3 0 0 F F 3 E * * / / 0 2 2 0 0 1 F F 3 E * * / / 0 0 2 3 0 2 F F 3 E * * / / 0 0 2 3 0 3 F F 3 E * Release Scan Spotting Beam Enable On Off Spotting Beam Timeout 0.25 0.5 1.0 1.
Other Controls 2.
Programming Bar Codes User IDs * / / 0 0 2 5 0 3 F F 3 E * * / / 0 0 2 6 $ M F F 3 E * * / / 0 0 2 6 $ * / / 0 0 2 6 % U F F 3 E * * / / 0 0 2 7 $ M F F 3 E * * / / 0 0 2 7 $ * / / 0 0 2 7 % U F F 3 E * LABEL PREFIX (CR) (TAB) I F F 3 E * None LABEL SUFFIX (CR) (TAB) I F F 3 E * None F-50 Falcon® 4400 Series with Windows Mobile®
Appendix G SDK Installation About the Software Development Kit (SDK): Microsoft provides most of the SDK functionality required to support Windows Mobile 5.0. Visit their Windows Mobile site to find documentation and download the Windows Mobile 5.0 Developer Evaluation Kit. http://msdn.microsoft.com/mobility/windowsmobile Select Downloads and locate the Windows Mobile 5.0 SDK for Pocket PC. Follow the instructions to obtain the most recent version.
SDK Installation New Functions Two new functions have been added to this SDK: 1. Get the current PSC defined OS ID int cdecl UnitGetOSType( void ); These defined values are located in unit_api.h /*** Operating System IDs ***/ #define OS_WINCE_NET0x00// Windows CE 4.2 or 5.0 #define OS_WIN_MOBILE0x01// Windows Mobile 2. Get the current PSC defined language type int cdecl UnitGetLanguage( void ); These defined values are located in unit_api.
Appendix H Glossary Many definitions for this Glossary were taken directly from the Microsoft Developer’s Network website at http://msdn.microsoft.com/library/default.asp. 1D bar code A traditional linear bar code. The code itself contains no information about the item to which it is assigned but represents a string of identifying numbers or letters. 2D bar code Two-dimensional (2D) bar codes permit the encoding of information about an item in addition to an identifying code.
Glossary Concatenate Arranges (strings of characters) into a connected list. control A standardized part of the window that can be manipulated to perform an action or display information. The most common controls are buttons to select options and scroll bars that for moving through a document or positioning text in a window. context sensitive help Tap > Help to open a help dialog about the specific windows application you are using.
GPS host PC system Global Positioning System. Windows Mobile-based Falcons can be set up to work with a GPS system. PC using the Microsoft Windows operating system and Falcon Management Utility (FMU) and/or ActiveSync. input panel Refer to on-screen keyboard. ISBN International Standard Book Number. A unique number assigned to each book to allow ease of ordering from any source: local bookstore, online book dealers, or directly from the publisher.
Glossary persistent state A state which is maintained after releasing a key. Alpha mode is a persistent mode. Also called a “sticky” state. A persistent state must be turned off by pressing the key again. PRG Product Reference Guide. program memory Memory that is used for stack and heap storage for both system and nonsystem applications. Nonsystem applications are taken from storage memory, uncompressed, and loaded into program memory for execution.
stylus The Falcon’s equivalent of a PC’s mouse. Use on a touch-sensitive display. Only a plastic tipped stylus should be used on a touch-sensitive display. Use to navigate the touchscreen display, select characters in the on-screen keyboard, select applications, and select tabs, fields and text within applications and dialogs. suspend mode The Falcon will go into a suspend or sleep mode when it is idle for a period of time. Suspend mode works and looks just like you have turned the unit off.
Glossary NOTES H-6 Falcon® 4400 Series with Windows Mobile®
Index ...
Index Trioptic F-26 UPC/EAN Extensions F-29 UPC-A F-26 UPC-E F-28 without parameters E-2 battery CAUTIONS 1-3, 1-4 disposal 1-4 failure 1-3 window 1-3 lithium-ion 1-3 tab 2-20 WARNINGS 1-2 battery charger four-slot A-3 beep duration, good-read E-35, F-47 good-read number E-35, F-46 tone, good-read E-35, F-47 volume E-34, F-45 Brightness Imager 2-8 button new B-15 OK B-4, B-8, B-11 X B-8, B-11 C cable serial D-1, D-2 calibration H-1 checksum H-1 Codabar 2-9, E-3, F-10 Code 128 2-9, E-8, F-10 Code 39 2-9, 2
Index defaults, restore B-6, B-7 delay B-16 delete B-9, B-15 device 2-9 device manager H-2 device partnership H-2 disable 2-7 dock which PSC dock to use A-2 document conventions 0-vi overview 0-v E EAN-13 2-9, E-9, F-12 EAN-8 2-9, E-11, F-14 edit B-15 embedded H-2 enable 2-10 address bar B-13 application selector B-14 checksum 2-10 Falcon Desktop B-6 read-ahead 2-9 enter key B-11 error 400 Invalid Syntax B-12 403 Request Forbidden B-12 404 Object Not Found B-12 501 Server Can’t Do That B-12 Couldn’t Find
Index good-read beep duration E-35, F-47 beep tone E-35, F-47 number of beeps E-35, F-46 H handle A-8 removing A-9 handstrap A-8 installing A-8 holster A-6 Home Page B-12 host PC system H-3 hotkey B-9, B-17 add new B-10 new B-9 I I.D.
Index N navigation key H-2 Network ID H-3 new B-14 button B-15 hotkey B-9 non-persistent state H-3 Not Available Offline B-12 note B-10 O OCR Check Characters E-42 OK button B-4, B-8, B-11 other controls E-34 overview B-1 overview, manual 0-v P parameters acceptable input E-1 bar codes E-3 bar codes without E-2 Codabar E-3 Code 128 E-8 Code 39 E-5 Code 93 E-7 code parameters E-1 default E-1 EAN-13 E-9 EAN-8 E-11 ID# E-1 Interleaved 2 of 5 E-12, E-13 label prefix E-36, F-50 label suffix E-36 MSI E-15 on/o
Index R save new settings 2-12 save to registry F-3 scan key 2-7 select with the stylus 0-vii selector application B-14, B-16 enable application B-14 send check digit 2-10 checksum 2-10 system digit 2-10 serial number 2-13 serial cable D-1, D-2 serial number Falcon Information 2-12 Serial Printer Adapter A-4 Server Is Busy B-12 set home page B-12 set ID character 2-7 set password B-6, B-7 settings modifying 2-1 shortcut menu H-4 Show Taskbar B-14 SNMP C-1, H-4 Concepts C-2 soft input panel H-3 softcase A
Index MSI E-15, F-19 PDF F-39 Pharmacode 39 (Code 32) E-16, F-21 RSS F-21, F-22, F-30 send identifiers E-35, F-49 Standard 2 of 5 E-19, F-24 Trioptic E-20, F-26 UPC/EAN Extensions E-23, F-29 UPC-A E-21, F-26 UPC-E E-22, F-28 system tray icons H-5 keyboard Indicators H-5 keyboard indicators H-5 volume beeper E-34, F-45 W wake up 1-2 Win tab B-13 windows controls 0-vii, B-13 X X button T tap stylus 0-vii task bar B-13 enabled B-14 task switcher B-17 Tethered Stylus A-11 Timeout Imager, Imager Timeout t
Index NOTES viii Falcon® 4400 Series with Windows Mobile®
Asia Pacific Germany Latin America PSC Hong Kong Hong Kong Telephone: [852]-2-584-6210 Fax: [852]-2-521-0291 PSC GmbH Darmstadt, Germany Telephone: 49 (0) 61 51/93 58-0 Fax: 49 (0) 61 51/93 58 58 PSC S.A., INC. Miami, Florida, USA Telephone: (305) 591-3222 Fax: (305) 591-3007 Australia Italy Spain and Portugal PSC Asia Pacific Pty Ltd. North Ryde, Australia Telephone: [61] (2) 9870 3200 Fax: [61] (2) 9878 8688 PSC S.p.A. Vimercate (MI), Italy Telephone: [39] (0) 39/62903.