Specifications
Bar Code Parameters
Product Reference Guide E-25
Aztec 
Code Max-
imum
This feature specifies the maxi-
mum allowable length of a label. 
The length includes check and 
data characters, if applicable. 
Maximum Label Length should be 
greater than or equal to Minimum 
Label Length.
0
B
2
D
1 - 3750 1 3750 3750
9
Aztec 
Code User 
ID
Specifies the symbology identifier 
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is 
set to 3. 
ASCII code zero (null) is 
used to indicate that an identifier is 
not to be sent for the symbology.
0
B
2
F
Any sin-
gle 
ASCII 
charac-
ter (00 = 
Off)
‘d’ ‘d’ ‘d’
9
DataMatrix Enter 1 for On 
and 0 for Off.
Datama-
trix 
Enable
Enables/disables the Datamatrix 
symbology.
0
B
0
0
On or 
Off
Off On On
9
Datama-
trix 
Minimum
Set the minimum bar code label 
length to be less than or equal to 
maximum label length.
0
B
2
0
1 - 1500 1 1500 1
9
Datama-
trix Maxi-
mum
This feature specifies the maxi-
mum allowable length of a label. 
The length includes check and 
data characters, if applicable. 
Maximum Label Length should be 
greater than or equal to Minimum 
Label Length.
0
B
2
1
1 - 1500 1 1500 1500
9
Code Parameter/ Description
I.
D. 
#
Accept
able 
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear 
Imager
2D 
Imag
er