Specifications
Programming Parameters
E-30 Falcon
® 
4400 Series with Windows
Mobile
®
MicroPDF-
417 Maxi-
mum
This feature specifies the maxi-
mum allowable length of a label. 
The length includes check and 
data characters, if applicable. 
Maximum Label Length should be 
greater than or equal to Minimum 
Label Length.
0
A
2
5
1 - 366 1 366 366
9
MicroPDF-
417 User 
Code ID
Specifies the symbology identifier 
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is 
set to 3. 
ASCII code zero (null) is 
used to indicate that an identifier is 
not to be sent for the symbology.
0
A
2
7
Any sin-
gle 
ASCII 
charac-
ter (00 = 
Off)
‘a’ ‘a’ ‘a’
9
QR Code Enter 1 for On 
and 0 for Off.
QR Code 
Enable
Enables/disables QR Code sym-
bology.
0
B
1
0
On or 
Off
Off On Off
9
QR Code 
Minimum
Set the minimum bar code label 
length to be less than or equal to 
maximum label length.
0
B
2
8
1 - 3500 1 3500 1
9
QR Code 
Maximum
This feature specifies the maxi-
mum allowable length of a label. 
The length includes check and 
data characters, if applicable. 
Maximum Label Length should be 
greater than or equal to Minimum 
Label Length.
0
B
2
9
1 - 3500 1 3500 3500
9
Code Parameter/ Description
I.
D. 
#
Accept
able 
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear 
Imager
2D 
Imag
er