Specifications
Programming Parameters
E-34 Falcon
® 
4400 Series with Windows
Mobile
®
Table E-5. Other Controls 
JPEG 
Imaging 
Quality
Specifies the level of quality an imager will 
use when taking images. Lower levels 
result in images which have greater levels 
of lost detail, but have smaller storage 
requirements and transmit faster.
0
C
2
A
0 to 99 
(lower to 
higher)
50 99 99
Imaging 
Gamma Cor-
rection
Specifies the amount of correction the 
imager applies when taking images. 
Gamma correction attempts to match the 
way the imager responds to light levels to 
that of the human eye.
0
C
2
B
0 (none), 
1 to 99 
(less to 
more)
00 0
Code Parameter/ Description
I.
D. 
#
Accep-
table 
Input
Defaults
Min Max Factory
Code Parameter/ Description
I.
D. 
#
Acceptable 
Input
Defaults
Min Max Factory
Other Controls Enter 1 for On and 0 for Off.
Enable Label 
Programming
Enables/disables the ability to perform 
label programming.
F
F
0
0
On or Off On On On
Beeper Volume
Adjusts the beeper volume.
F
F
2
0
00 = Off
00 - 09
(01 = Lowest;
07 = Highest;
08 = Higher;
09 = Lower)
07 07 07
Long Range 
Trigger Mode
Selects the Long Range Trigger mode.
0
0
0
0
On = Release 
Scan Off = 
Spot Timeout