Specifications
Bar Code Parameters
Product Reference Guide F-31
QR Code Enter 1 for On
and 0 for Off.
QR Code
Enable
Enables/disables QR Code sym-
bology.
0
B
1
0
On or
Off
Off On Off
9
QR Code
Minimum
Set the minimum bar code label
length to be less than or equal to
maximum label length.
0
B
2
8
1 - 3500 1 3500 1
9
QR Code
Maximum
This feature specifies the maxi-
mum allowable length of a label.
The length includes check and
data characters, if applicable.
Maximum Label Length should be
greater than or equal to Minimum
Label Length.
0
B
2
9
1 - 3500 1 3500 3500
9
QR Code
User ID
Specifies the symbology identifier
(if any) that is sent when parame-
ter Send Code ID (Index 0025) is
set to 3.
ASCII code zero (null) is
used to indicate that an identifier is
not to be sent for the symbology.
0
B
2
B
Any sin-
gle
ASCII
charac-
ter (00 =
Off)
‘c’ ‘c’ ‘c’
9
Code Parameter/ Description
I.
D.
#
Accept
able
Input
Defaults Scanner Type
Min Max
Fac-
tory
Laser/
Linear
Imager
2D
Imag
er