PARAMETER SET (SP)
The PARAMETER SET command is used to set conditions for communicating with ID Tags. The
various parameters are set in the Hand-held Reader Writer.
The Hand-held Reader Writer does not need to be reset when internal settings are changed. The new settings are
effective immediately.
A memory error will occur if the power supply is interrupted while parameters are being changed.
Process code (Upper digit) Specifies the process to perform for the parameter.
0: Change the internal setting.
1: Read internal setting.
9: Return internal setting to default value.
Process code (Lower digit) Specifies the parameter.
1: Inter-character monitoring time
2: Response delay time
4: Auto command cancel time
H: Write protection setting
J: Protocol switch
Parameter data (for
changed parameters only)
Data No.
(See note.)
Settable values
1 Specify 4 decimal digits. 0000 to 9999 (ms)
0000: No monitoring, Default value: 0100 (ms)
2 Specify 2 decimal digits. 00 to 99 (ms)
00: No delay, Default value: 20 (ms)
4 Specify 2 decimal digits. 01 to 99 (s)
Default value: 60 (s)
H 00: Write protection OFF
01: Write protection ON (default value)
J 00: V600 protocol (default value)
01: V680 protocol
Note: The data number of the parameter data is the number specified for the lower digit of the process code.
The settable values for the data number are the same as for the parameter specified by the lower digit of the process code.
End code Indicates the execution result for the command.
00: Normal completion
For details on end codes, refer to End code List.
p.104
Parameter data Attached only when parameter data is being obtained.
Command
SP
××
2
2
CR
××
0 to 4
2
Upper digit Lower digit
××
Parameter data
(for changed
parameters only)
Command
code
Terminator
Process code
Response
S
00
22
2
CR
××
P
××
Parameter data
Command
code
Terminator
0 to 4
End code