User`s manual
39
RFID System
User's Manual
Section 2
V680-CH1D-PSI Communications Preparations
Section 2
Communications Preparations
Auto Command Cancel Time
The auto command cancel time is used to set the amount of time from after an auto command is sent
until the command processing will be aborted.
After waiting for the tag for a fixed period of time, an "ID Tag non-existent" error (error code: 72) will be
returned to the host device.
Write Protection Enable Setting
The write protection enable setting can be used to enable or disable write protection.
00: Write protection function disabled
01: Write protection function enabled default value
For details on write protection settings, refer to Write Protection Function in Section 4.
p.107
Protocol Switch
The protocol switch is used to set whether the Hand-held Reader Writer will use the V680 command
format or the V600 command format.
0: V600 commands (default value)
1: V680 commands
For details, refer to Section 3 Commands.
p.43
Setting range
0 to 99 (s)
Note: Default value: 60 (s)
External input
Command
Auto command
cancel time
Response
Error code: 72
Host device to
Hand-held Reader
Writer
Hand-held Reader
Writer to host device