Command and Response Formats
The formats of commands sent from the host device to the Hand-held Reader Writer and responses
returned from the Hand-held Reader Writer to the host device are described below.
The command and response both consist of a single frame. Each frame (including the terminator)
consists of up to 2,114 characters. (When specifying hexadecimal for using the WRITE command, the
maximum is 4,218 characters.)
■ Command Frame
■ Response Frame
Note: Other than the above items, the same data as the command frame is returned in the response.
Name Description
Command code Contains the two-character code (see page 75) that indicates command.
Communications specification Contains the two-character code that indicates the method used to communicate with the ID Tag (see page
47.)
Data Contains the parameters or write data used to execute the command.
• Data settings, processing specifications
• Start address
• Write data, number of bytes to be written
• Number of read bytes
• Number of check block bytes, decrement count
• Specified data
• Message data
• Parameter data
• Baud rate, data length, parity, and stop bit specifications
• Auto command OFF specification
• Settings for the TR command, settings for the FN command, and system setting data
Terminator Indicates end of command/response.
Name Description
End code Indicates the execution result for the command.
For information on end codes, refer to End Codes.
p.69
Fixed value Always 1.
Resend flag Always 0.
Data The data for the response.
• Read data
•UID
• Processing terminate timing
• Parameter data
• Message data
• Model information
××
×
2
2
CR
×
…×
n
×
Communications
specification
××
2
1 frame (maximum frame length: 2,114 characters)
Command
code
Data Terminator
××
×
2
2
CR
×
…×
n
×
××
2
10
11
Command
code
Data
Terminator
End code
Fixed
value
Resend
flag