User`s manual

62
Section 3
V680 Commands
RFID System
User's Manual
Section 3
Commands
Communications Subcommands
Communications subcommands are used together with communications commands. Communications
with the ID Tag cannot be performed using only these subcommands.
COMMAND PROCESSING TERMINATE (AA)
Terminates the processing of the communications commands and restores the command wait status.
ABORT (XZ)
This command is used to restore the Hand-held Reader Writer to command wait status when there is
no response from the Hand-held Reader Writer due to some problem during communications with the
host device or with an ID Tag.
The ABORT (XZ) command can be used only with the V680-CH1D.
Do not use it with the V680-CHUD.
None
Processing specification Always 0.
Fixed value Always 1.
End code Indicates the execution result for the command.
00: Normal completion
15: Command processing not executed.
For details on end codes, refer to End Codes.
p.69
Fixed value Always 1.
Resend flag Always 0.
Termination timing Indicates the timing for terminating command processing.
00: Terminate before ID Tag detection.
01: Terminate during ID Tag detection.
Command
AA
1
2
2
CR
0
11
Command
code
Terminator
Fixed
value
Pro-
cessing
specifi-
cation
Response
AA
0
2
2
CR
1
00
2
11
2
Command
code
Terminator
End code
Fixed
value
Resend
flag
Processing
terminate
timing
Command
XZ
2
2
CR
Command
code
Terminator
Response