User`s manual

85
RFID System
User's Manual
Section 3
V600 Commands
Section 3
Commands
BUTTON WRITE (BW)
After this command is received by the Hand-held Reader Writer, data is written to the ID Tag by press-
ing the activate switch. If the activate switch is pressed and the ID Tag is not in the communications
area, an error response (end code: 72 = ID Tag non-existent) will be returned.
Processing Area Number: 1
Processing Area Number: 2
Data setting Sets the code format used to send responses for write data.
A: ASCII
H: Hexadecimal
When multiple processing areas are used, ASCII and hexadecimal can be specified at the same
time within a single command frame.
Processing area number
setting
Specifies the processing area number.
Setting range: 1 to 9, A (A = 10)
Write area start address Specifies the start address of the area in the ID Tag to be written to in 4-digit hexadecimal.
Setting range: 0000 to FFFF hex
When multiple processing areas are used, specify the areas in order starting from the smallest
address. The same area cannot be specified twice.
Number of write bytes When multiple processing areas are used, specifies the number of bytes to be written to the ID Tag
in 2-digit hexadecimal.
The maximum number of bytes that can be written at one time is 256 bytes.
ASCII: 256 bytes (256 characters)
Hexadecimal: 256 bytes (512 characters)
Setting range: 01 to FF hex
When multiple processing areas are used, set so that the total number of bytes to be written for all
areas is within 256 bytes, as follows:
Area (1) bytes +...+ Area (N) bytes 256 bytes
Write data Indicates the data to be written to the ID Tag.
The characters in ASCII indicate the number of write bytes and the characters in hexadecimal indi-
cate the number of write bytes x 2.
End code Indicates the execution result for the command.
The end code 00 indicates normal completion.
For details on end codes, refer to End code List.
p.104
Command
××
BW
××
A/H 1
××
211 4
2
CR
n
××
Command
code
Write data
Terminator
Data
setting
Processing
area
number
setting
Write area
start address
××
BW
××
A/H 2
××
211 4 2
…××
n
2
CRA/H
1
××
××××
42
…××
n
Area (1) setting
Write data Terminator
Area (2) setting
Data
setting
Number of
write bytes
Write data
Command
code
Data
setting
Processing
area number
setting
Write area
start address
Number of
write bytes
Write area
start address
Response
BW
00
22
2
CR
Command
code
Terminator
End code