Developers guide
Chapter 14: Scanners
Configuring Scanner Properties
Psion Teklogix Mobile Devices SDK Developers Guide 91
Send a character to the application mode
In this mode, double-clicking the scanner-associated trigger sends a single pre-selected character
defined in the Click Data setting to the application.
These settings control this process for the internal scanner as well as for an external non-
decoded scanner.
Control Panel:
These settings can be changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
14.3.1.2 Display, Beep, And Logging Options
These settings control how bar codes are displayed on the screen, when beeps are generated, and
whether bar code scans are logged. These settings are applied to the internal scanner as well as an
external non-decoded scanner.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
•Tab
Options
• Menu Item
Double Click
Scanner Setting Key: Scs
Scanner Setting Name Minimum Maximum Default Control Panel Name
Click Time 0 ms 1000 ms 250 ms Click Time
Click Data 0 0xFFFF 0 Click Data
•Tab
Options
• Menu Item
Display
Scanner Setting Key: Scs
Scanner Setting Name Minimum Maximum Default Control Panel Name
Scan Result 0 = off 1 = on 1 Scan Result
Scan Indic 0 = off 1 = on 1 Scan Indicator
Result Time 0 s 20 s 0 s Scan Result Time
Scan Good Beep 0 = off 1 = on 1 Good Scan Beep
Scan Failed Beep 0 = off 1 = on 1 Bad Scan Beep
Scan Log File 0 = off 1 = on 0 Scan Log File