Developers guide
Psion Teklogix Mobile Devices SDK Developers Guide 101
Chapter 14: Scanners
Configuring Bar Code Symbologies
Code 128 Settings
14.3.3.4 Code 128 Settings
Non-decoded Scanner
These settings apply to an internal or external non-decoded scanner using the Code 128
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Decoded Scanner
These settings apply to an internal decoded scanner using the Code 128 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Imager (Deprecated)
These settings apply to an internal imager scanner using the Code 128 symbology.
•Tab
Barcodes
• Scanner:
Non-decoded
• Menu Item
Code 128
Scanner Setting Key: Barcode\C128
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Include Sym 0 = off 1 = on 1 Include Sym
Variant Mode 0 3 1 Variations
Transmit Code ID Char 0 = off 1 = on 0 Transmit Code ID Char
•Tab
Barcodes
• Scanner:
Decoded (internal)
• Menu Item
Code 128
Scanner Setting Key: Barcode\C128\Decoded
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
UCC EAN 128 0 = off 1 = on 1 Enable GS1-128/GS1 US
ISBT 128 0 = off 1 = on 0 Enable ISBT 128
Decode Performance 0 = off 1 = on 1 Decode Performance
Decode Performance Level 1 3 1 Decode Perf. Level