Developers guide
Psion Teklogix Mobile Devices SDK Developers Guide 103
Chapter 14: Scanners
Configuring Bar Code Symbologies
EAN 13 Settings
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the Code
128symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
14.3.3.5 EAN 13 Settings
Non-decoded Scanner
These settings apply to an internal or external non-decoded scanner using the EAN 13 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
•Tab
Barcodes
• Scanner:
Decoded (HHP)
• Menu Item
Code 128
Scanner Setting Key: Barcode\C128\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
ISBT Concatenation 0 = off 1 = on 0 ISBT Concatenation
Length Min 0 80 0 Minimum Length
Length Max 0 80 80 Maximum Length
•Tab
Barcodes
• Scanner:
Non-decoded
• Menu Item
EAN 13
Scanner Setting Key: Barcode\EAN13
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Enable Bookland 0 = off 1 = on 0 Enable Bookland EAN
Inc Country 0 = off 1 = on 1 Include Country
Include Chk 0 = off 1 = on 1 Include Check
Addendum 0 2 0 Addendum
Transmit Code ID
Character
0 = off 1 = on 0 Transmit Code ID Char