Developers guide

Chapter 14: Scanners
Configuring Bar Code Symbologies
Psion Teklogix Mobile Devices SDK Developers Guide 107
Intermec ISCP Imager
These settings apply only to the Intermec ISCP imager acting as a decoded scanner using the EAN
8 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the EAN 8
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
•Tab
Barcodes
Scanner:
Decoded (Intermec ISCP)
Menu Item
EAN 8
Scanner Setting Key: Barcode\EAN8\ICSP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Transmit Check Digit 0 = off 1 = on 1 Transmit Check Digit
Transmit as EAN-13 0 = off 1 = on 0 Convert to EAN 13
•Tab
Barcodes
Scanner:
Decoded (HHP)
Menu Item
EAN 8
Scanner Setting Key: Barcode\EAN8\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Check Digit 0 = off 1 = on 1 Check Digit
2 Digit Addendum 0 = off 1 = on 0 Addendum Add-on 2
5 Digit Addendum 0 = off 1 = on 0 Addendum Add-on 5
Addendum Required 0 = off 1 = on 0 Addendum Required
Addendum Separator 0 = off 1 = on 1 Addendum Separator