Developers guide

Chapter 14: Scanners
Configuring Bar Code Symbologies
Psion Teklogix Mobile Devices SDK Developers Guide 111
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Decoded Scanner
These settings apply to an internal decoded scanner using the UPC E symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Intermec ISCP Imager
These settings apply only to the Intermec ISCP imager acting as a decoded scanner using the UPC
E symbology.
•Tab
Barcodes
Scanner:
Imager
Menu Item
UPC E
Scanner Setting Key: Barcode\UPCE\Imager
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Addendum 0 2 0 Addendum
•Tab
Barcodes
Scanner:
Decoded (internal)
Menu Item
UPC E
Scanner Setting Key: Barcode\UPCE\Decoded
Scanner Setting Name Minimum Maximum Default Control Panel Name
UPCE Enabled 0 = off 1 = on 1 Enable UPC-E
UPCE1 Enabled 0 = off 1 = on 0 Enable UPC-E1
UPCE Transmit Check Digit 0 = off 1 = on 1 UPC-E Check Digit
UPCE1 Transmit Check
Digit
0 = off 1 = on 1 UPC-E1 Check Digit
UPCE Preamble 0 2 1 UPC-E Preamble
UPCE1 Preamble 0 2 1 UPC-E1 Preamble
Convert UPCE to UPCA 0 = off 1 = on 0 Conv. UPC-E to UPC-A