Developers guide
Chapter 14: Scanners
Configuring Bar Code Symbologies
112 Psion Teklogix Mobile Devices SDK Developers Guide
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the UPC E
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
•Tab
Barcodes
•Scanner:
Decoded (Intermec ISCP)
• Menu Item
UPC E
Scanner Setting Key: Barcode\UPCE\ICSP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
UPC-E1 Enabled 0 = off 1 = on 0 Enable UPC-E1
Transmit Check Digit 0 = off 1 = on 1 Transmit Check Digit
Transmit Number System 0 = off 1 = on 1 Transmit Number System
Transmit as UPC-A 0 = off 1 = on 0 Convert to UPC-A
•Tab
Barcodes
•Scanner:
Decoded (HHP)
• Menu Item
UPC E
Scanner Setting Key: Barcode\UPCE\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
UPC-E1 Enabled 0 = off 1 = on 0 Enable UPC-E1
Expand 0 = off 1 = on 0 Expand
Check Digit 0 = off 1 = on 1 Check Digit
Number System 0 = off 1 = on 1 Transmit Number System
2 Digit Addendum 0 = off 1 = on 0 Addendum Add-on 2
5 Digit Addendum 0 = off 1 = on 0 Addendum Add-on 5
Addendum Required 0 = off 1 = on 0 Addendum Required
Addendum Separator 0 = off 1 = on 1 Addendum Separator