Developers guide
Chapter 14: Scanners
Configuring Bar Code Symbologies
118 Psion Teklogix Mobile Devices SDK Developers Guide
SDK:
These settings can be changed and queried through the SDK as follows:
Intermec ISCP Imager
These settings apply only to the Intermec ISCP imager acting as a decoded scanner using the Code
93 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the Code 93
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Scanner Setting Key: Barcode\C93\Imager
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
•Tab
Barcodes
•Scanner:
Decoded (Intermec ISCP)
• Menu Item
Code 93
Scanner Setting Key: Barcode\C93\ICSP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Length L1 0 255 1 Set Length L1
•Tab
Barcodes
•Scanner:
Decoded (HHP)
• Menu Item
Code 93
Scanner Setting Key: Barcode\C93\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 1 Enabled
Length Min 0 80 0 Minimum Length
Length Max 0 80 80 Maximum Length