Developers guide
Chapter 14: Scanners
Configuring Bar Code Symbologies
Psion Teklogix Mobile Devices SDK Developers Guide 121
Decoded Scanner
These settings apply to an internal decoded scanner using the Interleaved 2 of 5 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Imager (Deprecated)
These settings apply to an internal imager scanner using the Interleaved 2 of 5 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Scanner Setting Key: Barcode\I25\Imager
Intermec ISCP Imager
These settings apply only to the Intermec ISCP imager acting as a decoded scanner using the In-
terleaved 2 of 5 symbology.
•Tab
Barcodes
• Scanner:
Decoded (internal)
• Menu Item
Interleaved 2 of 5
Scanner Setting Key: Barcode\I25\Decoded
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Length L1 0 14 14 Set Length L1
Length L2 0 14 0 Set Length L2
Check Digit Verification 0 = off 1 = on 0 Check Digit Verification
Transmit Check Digit 0 = off 1 = on 0 Transmit Check Digit
Convert to EAN 13 0 = off 1 = on 0 Convert to EAN 13
•Tab
Barcodes
• Scanner:
Imager
• Menu Item
Interleaved 2 of 5
Scanner Setting Key: Barcode\I25\Imager
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Check Digit Verification 0 = off 1 = on 0 Check Digit Verification
Include Check 0 = off 1 = on 0 Include Check