Developers guide
Chapter 14: Scanners
Configuring Bar Code Symbologies
Psion Teklogix Mobile Devices SDK Developers Guide 123
14.3.3.14MSI Plessey Settings
Non-decoded Scanner
These settings apply to an internal or external non-decoded scanner using the MSI Plessey
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Decoded Scanner
These settings apply to an internal decoded scanner using the MSI Plessey symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
•Tab
Barcodes
• Scanner:
Non-decoded
• Menu Item
MSI Plessey
Scanner Setting Key: Barcode\MSI
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
One Chk Digits 0 = off 1 = on 1 One Check Digit
Include Chk 0 = off 1 = on 0 Include Check
Tra n s m it Code ID
Character
0 = off 1 = on 0 Transmit Code ID Char
•Tab
Barcodes
• Scanner:
Decoded (internal)
• Menu Item
MSI Plessey
Scanner Setting Key: Barcode\MSI\Decoded
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Length L1 6 55 6 Set Length L1
Length L2 6 55 55 Set Length L2
Check Digits 0 1 0 Check Digits
Transmit Check Digit 0 = off 1 = on 0 Transmit Check Digit
Check Digit Algorithm 0 1 1 Check Digit Algorithm