Developers guide

Chapter 14: Scanners
Configuring Bar Code Symbologies
124 Psion Teklogix Mobile Devices SDK Developers Guide
Intermec ISCP Imager
These settings apply only to the Intermec ISCP imager acting as a decoded scanner using the MSI
Plessey symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the MSI Plessey
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
•Tab
Barcodes
•Scanner:
Decoded (Intermec ISCP)
Menu Item
MSI Plessey
Scanner Setting Key: Barcode\MSI\ICSP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Enabled Plessey 0 = off 1 = on 0 Enable Plessey
Check Digit Verification 1 2 2 Check Digit Verification
Transmit Check Digit 0 = off 1 = on 1 Transmit Check Digit
Plessey Transmit Check
Digit
0 = off 1 = on 0 Plessey Transmit Check
Digit
Length L1 0 255 6 Minimum Length
Plessey Length L1 0 255 0 Plessey Minimum Length
•Tab
Barcodes
•Scanner:
Decoded (HHP)
Menu Item
MSI Plessey