Developers guide
Chapter 14: Scanners
Configuring Bar Code Symbologies
126 Psion Teklogix Mobile Devices SDK Developers Guide
SDK:
These settings can be changed and queried through the SDK as follows:
14.3.3.16Discrete 2 of 5 Settings
Non-decoded Scanner
These settings apply to an internal or external non-decoded scanner using the Discrete 2 of 5
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
Decoded Scanner
These settings apply to an internal decoded scanner using the Discrete 2 of 5 symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
Scanner Setting Key: Barcode\Matrix25\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Length Min 1 80 4 Minimum Length
Length Max 1 80 80 Maximum Length
•Tab
Barcodes
•Scanner:
Non-decoded
• Menu Item
Discrete 2 of 5
Scanner Setting Key: Barcode\D25
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Mod Chk Base 0 = off 1 = on 0 MOD 10 Check
ItfChk 0 = off 1 = on 0 ITF Check
Include Chk 0 = off 1 = on 0 Include Check
Tran s m i t C o d e ID
Character
0 = off 1 = on 0 Transmit Code ID Char
•Tab
Barcodes
•Scanner:
Decoded (internal)
• Menu Item
Discrete 2 of 5