Developers guide

Chapter 14: Scanners
Configuring Bar Code Symbologies
Psion Teklogix Mobile Devices SDK Developers Guide 139
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
14.3.3.26Code 49 Settings
HHP Imager
These settings apply only to the HHP imager acting as a decoded scanner using the Code 49
symbology.
Control Panel:
These settings are changed through the Control Panel Scanner Properties as follows:
SDK:
These settings can be changed and queried through the SDK as follows:
14.3.3.27Codablock Settings
Intermec ISCP Imager
These settings apply only to the Intermec ISCP imager acting as a decoded scanner using the Cod-
ablock symbology.
•Tab
Barcodes
Scanner:
Decoded (HHP)
Menu Item
Code 16K
Scanner Setting Key: Barcode\C16K\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Length Min 1 160 1 Minimum Length
Length Max 1 160 160 Maximum Length
•Tab
Barcodes
Scanner:
Decoded (HHP)
Menu Item
Code 49
Scanner Setting Key: Barcode\C49\HHP
Scanner Setting Name Minimum Maximum Default Control Panel Name
Enabled 0 = off 1 = on 0 Enabled
Length Min 1 81 1 Minimum Length
Length Max 1 81 81 Maximum Length