User`s manual

16 V680 Series RFID System
ID Sensor Units
Note: When connected to the V680-H01: 280 mA
Functional Specifications of ID Sensor Units
Note 1. Cannot be used for communications with the V680-D1KP@@.
2. For details, refer to the User's Manual (Cat. No. Z248 or Z262).
Handheld Reader Writers
Note 1. Refer to the User's Manual (Cat. No. Z272) for details.
2. This does not include the connector section. The main unit is not resistant to chemical or oils.
Item Model CJ1W-V680C11 CJ1W-V680C12 CS1W-V680C11 CS1W-V680C12
Current
consumption
Internal: 5 V 260 mA 320 mA 260 mA 320 mA
Internal:
24 V/26 V
130 mA (See note.) 260 mA 125 mA (See note.) ---
External: 24 V --- --- --- 360 mA
Dielectric strength 1,000 VAC for 1 minute
Insulation resistance 20 m min. at 500 VDC
Ambient operating
temperature
0 to 55°C
Ambient operating humidity 10% to 90% (with no condensation)
Ambient storage temperature 20 to 75°C
Degree of protection Mounted in panel (IP30)
Vibration resistance
10 to 57 Hz variable vibration, 0.075-mm double amplitude and 57 to 150 Hz variable vibration at 9.8 m/s
2
acceleration, with 10 sweeps in X, Y, and Z directions for 8 minutes each
Shock resistance
147 m/s
2
in X, Y, and Z directions 3 times each
Appearance 31 × 65 × 90 mm (excluding protrusions) 35 × 130 × 101 mm (excluding protrusions)
Item Model CJ1W-V680C11 CJ1W-V680C12 CS1W-V680C11 CS1W-V680C12
Communications control
protocol
Special protocol for CS1 and CJ1 PLCs
Number of Read/Write Head
connections
1212
Commands Supported commands: Read, Write, Bit Set/Bit Clear, Mask Bit Write, Calculation Write, Data Fill, Data Check,
Number of Writes Control, Copy, Read with Error Correction/Write with Error Correction, UID Read, and Noise
Measurement.
The following communications options are supported: Single trigger, Single auto, Repeat auto, FIFO trigger, FIFO
repeat (See note.), Multi-access trigger, and Multi-access repeat (See note.)
Data transfer quantity 2,048 bytes max. (160 bytes/scan)
Diagnostic function (1) CPU watchdog timer
(2) Communications error detection with ID Tag
(3) Antenna power supply error
Monitoring/testing
functions
Tag communications can be tested in Test Mode. Status is displayed by LED indicators.
Number of allocated words 10 words 20 words 10 words 20 words
Item Model V680-CHUD 0.8M V680-CHUD 1.9M V680-CH1D V680-CH1D-PSI
Power supply voltage 5 VDC±5%
Current consumption 500 mA max. (for a power supply voltage of 5.0 V)
Insulation resistance 50 M min. (at 500 VDC) between connector and case
Dielectric strength 1,000 VAC, 50/60 Hz for 1 min (leakage current: 1 mA max.) between connectors and case
Vibration resistance Destruction: 10 to 150 Hz, 0.2-mm double amplitude, with 10 sweeps for 8 min each in 6 directions
Shock resistance
Destruction: 150 m/s
2
, 3 times each in X, Y, and Z directions
Ambient operating
temperature during
communication
0 to +40°C
Ambient operating humidity
during communication
35% to 85% (with no condensation)
Ambient storage
temperature
25 to +65°C
Ambient storage humidity 35% to 85% (with no condensation)
Degree of protection IEC 60529: IP63 (See note 2.)
Cable length 0.8 m1.9 m2.5 m0.8 m
Weight Approx. 110 g
(including connector and
cable)
Approx. 140 g
(including connector and
cable)
Approx. 170 g
(including connector and
cable)
Approx. 120 g
(including connector and
cable)