User`s manual

34 V680 Series RFID System
8-/32-Kbyte Memory ID Tag
V680-D8KF@@, V680-D32KF@@ (used in combination with the V680-HS@@ Read/Write Antenna and V680-HA63B Amplifier Unit)
Note 1. These are the TAT values for a baud rate of 115,200 bps. For information on the TAT for baud rates other than 115,200 bps, refer to the
User's Manual.
2. When multi-access or FIFO is selected as the transmission option, the transmission time will be the same as in normal mode even when
the transmission speed is set to high-speed mode.
3. The value given for TAT data assumes that communications settings for the V680-CA5D01/02-V2 ID Controller are as follows:
Data length: 8 bits, Stop bits: 1, Parity: Odd.
In this example, communications are continuous, with no gaps between characters.
4. The number of bytes of TAT data is the number of bytes when ASCII is specified as the code.
Controller or ID Sensor
Unit transmission
speed setting
Command Write verification
setting
Number of bytes to
processed (byte)
TAT (ms) (See note 1.)
Normal mode Read --- 100 172
256 388
512 746
1,000 1,430
2,000 2,820
Write Yes 100 231
256 494
512 929
1,000 1,759
2,000 3,449
No 100 192
256 408
512 766
1,000 1,450
2,000 2,840
High-speed mode
(See note 2.)
Read --- 100 117
256 255
512 485
1,000 925
2,000 1,815
Write Yes 100 163
256 348
512 655
1,000 1,241
2,000 2,431
No 100 142
256 296
512 551
1,000 1,040
2,000 2,030