User manual

Chapter 5: Configuration
Code 39 Settings
132
Psion Teklogix 8525/8530 Vehicle-Mount Computer User Manual
before it processes the data through the AIAG feature; if the prefix is
stripped, the data is not identified as AIAG.
Error Accept
If the “Err Accept” and “AIAG Strip” parameters are enabled (set to ‘ON’), all label
data without an AIAG identifier character is accepted. If the “Err Accept” parameter
is disabled and the “AIAG Strip” parameter is enabled (set to ‘ON’), the label data is
not accepted.
Mod Checks
Tapping on this option displays a list of options.
None
If you choose ‘None’, a check is not executed.
Mod 43 Check
If this parameter is enabled (set to ‘ON’), the Mod 43 check digit is calculated.
Mod 10 Check
If this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated.
Field Size/Chars
Field Size
The field size is the length of the field after the first character is stripped and
the prefix and suffix characters are added. If the field size is non-zero, only
bar codes of that length are passed through.