User's Manual
Table Of Contents
- Peripheral Devices & Accessories 6
- 6.1 Carrying Accessories
- 6.2 The Battery
- 6.3 Adaptor Cable Options
- 6.4 Chargers And Docking Stations: General Information
- 6.5 CH4000 Desktop Docking Station
- 6.5.4 Cleaning The CH4000
- 6.5.5 Troubleshooting
- 6.5.5.1 Docking Station Does Not Seem To Power On.
- 6.5.5.2 The Ikôn Charge Indicator LED Stays Off.
- 6.5.5.3 The Ikôn Charge Indicator LED Is Fast Flashing Green.
- 6.5.5.4 Spare Battery LED Fast Flashes Green With A Battery Installed.
- 6.5.5.5 Spare Battery LED Does Not Turn On When A Battery Is Installed.
- 6.7 AC Wall Adaptor: Model No. PS1050 - G1
- 6.8 Automotive Power Adaptor: Model No. CH3050
- 6.9 The CH1000 Non-Powered Vehicle Cradle
- 6.10 The CH1005A Powered Vehicle Cradle
- 6.11 Scanners And Imagers
- 6.12 Bluetooth Peripherals
- Specifications 7
188 Ikôn Rugged PDA (Windows CE 5.0) User Manual
Chapter 5: Configuration
Decoded (ISCP)
Code 93
5.14.3.10 Code 93
Enabled
Set this parameter to on to enable “Code 93”.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).
Field Size/Chars
Refer to “Field Size/Chars” on page 170 for details.
5.14.3.11 Codabar
Enabled
Set this parameter to on to enable “Codabar”.
Start/Stop Transmit
Codabar can use the following sets of characters as start and stop characters:
a, b, c, d
A, B, C, D
a, b, c, d, /, t, n, *, e
DC1, DC2, DC3, DC4
Thus, when a set is chosen, the first and last digits of a Codabar message must be one of
those characters and the body of the message should not contain these characters. Setting
this parameter to Not Transmitted strips the start and stop characters from this bar code.
CLSI Library System
When enabled, spaces are inserted after characters 1, 5, 10 in the 14-character label (used in
the USA by libraries using the CLSI system).
Check Digit Verification
When enabled, this parameter checks the integrity of a symbol to ensure it complies with a
specified algorithm—either USS (Uniform Symbology Specification) or OPCC (Optical
Product Code Council).
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.