User's Manual
Table Of Contents
- Peripheral Devices & Accessories 6
- 6.1 Carrying Accessories
- 6.2 The Battery
- 6.3 Adaptor Cable Options
- 6.4 Chargers And Docking Stations: General Information
- 6.5 CH4000 Desktop Docking Station
- 6.5.4 Cleaning The CH4000
- 6.5.5 Troubleshooting
- 6.5.5.1 Docking Station Does Not Seem To Power On.
- 6.5.5.2 The Ikôn Charge Indicator LED Stays Off.
- 6.5.5.3 The Ikôn Charge Indicator LED Is Fast Flashing Green.
- 6.5.5.4 Spare Battery LED Fast Flashes Green With A Battery Installed.
- 6.5.5.5 Spare Battery LED Does Not Turn On When A Battery Is Installed.
- 6.7 AC Wall Adaptor: Model No. PS1050 - G1
- 6.8 Automotive Power Adaptor: Model No. CH3050
- 6.9 The CH1000 Non-Powered Vehicle Cradle
- 6.10 The CH1005A Powered Vehicle Cradle
- 6.11 Scanners And Imagers
- 6.12 Bluetooth Peripherals
- Specifications 7
190 Ikôn Rugged PDA (Windows CE 5.0) User Manual
Chapter 5: Configuration
Decoded (ISCP)
Code 11
Field Size/Chars
Refer to “Field Size/Chars” on page 170 for details.
5.14.3.13 Code 11
Enabled
Set this parameter to on to enable “Code 11”.
Check Digit Verification
The available options for this parameter are MOD 10 Check and Double MOD 10
Check.This parameter uses the specified algorithm of the option you've chosen to ensure the
integrity of the symbol data before transmitting. If the data does not contain that algorithm,
the data is not transmitted.
Transmit Check Digit
If the check digit is to be transmitted with the data, this parameter must be enabled.
Minimum Length
Minimum lengths for the bar code can be set from 0 to 255. The length of a code refers to
the number of characters (i.e., human readable characters), including check digit(s).
Field Size/Chars
Refer to “Field Size/Chars” on page 170 for details.
5.14.3.14 Interleaved 2 of 5
Enabled
Set this parameter to on to enable “Interleaved 2 of 5”.
Reading Range
This parameter determines the reading distance from which a bar code can be successfully
scanned. The default setting, Extended, allows for increased reading distance.
Check Digit Verification
The available options for this parameter are Disabled, MOD 10 Check and French CIP.
“Check Digit Verification” uses the specified algorithm of the option you've chosen to
ensure the integrity of the symbol data before transmitting. If the data does not contain that
algorithm, the data is not transmitted.