01
TXDATA2 Example Display
Title TXDATA2
Summary
Enables the transmitter, with a simplified hop sequence
designated by
Country Code and sets output Power (Ext, Int).
Payload is PRBS9 data (Default DH1).
Receiver is not operating.
Packet type and duty cycle can be configured. Refer to
Configuration Commands section.
Related Test
Spec Name
TRM/CA/01/C (output power), TRM/CA/02/C (power density)
Test Arguments
Country Code = 0 to 3 (Default = 0)
Return Data
None
Use RF Analyser to check carrier output.
Exit Click on Reset Chip or select another TXDATA command.