User's Manual Part 2
Psion Teklogix 7535 Hand-Held Computer User Manual 199
Chapter 6: Tekterm Application
Screen
To change values:
• Press the <UP> or <DOWN> arrow key to highlight a function key.
• Press the <TAB> key to move through the string of values.
• Either type new values, or press the <LEFT> or <RIGHT> arrow key to
change the values.
6.18.1.2 Screen
# of Pages
This parameter defines how many pages are accessible to application programs. The
ANSI control functions – Next Page (NP) and Previous page (PP) – are used to
select another page. These pages are independent of each other so that if lines of text
scroll off a page, the other pages are unaffected.
There is no error indication from the hand-held computer if the memory required by
the selected number and size of pages exceeds the memory available in the
computer.
# of Rows
This parameter defines the logical page length (in lines) used by the host computer
application. Emulator systems trim the host application screens to this length. This
page length cannot be smaller than the length of the hand-held’s display. Display
panning is used if the page is longer than the display.
Note: The value in this parameter must be an even number.
# of Pages 4 0..16
# of Rows 24 4..60
# of Cols
80 80 or 132
Default Font 16x30 see text
80-col. Font 16x30 see text
132-col. Font 16x30 see text
Video » see text
Label F1-F6 » see text
Colour override N » see text
Range
Screen
05