User's Manual
Table Of Contents
- Cover
- Program License Agreements
- TABLE OF CONTENTS
- Approvals And Safety Summary
- Introduction 1
- Basic Checkout 2
- Getting To Know Your 7535 3
- 3.1 Features Of The 7535
- 3.2 The Battery
- 3.3 Switching The 7535 Hand-Held On And Off
- 3.4 The Keyboard
- 3.5 The Display
- 3.6 7535 Indicators
- 3.7 Internal Scanners
- 3.8 Connecting & Disconnecting Tethered Peripherals
- 3.9 Monitoring The Battery And Maximizing Run Time
- 3.10 Monitoring The Network Connection
- 3.11 Uploading Data In A Docking Station
- 3.12 General Maintenance
- Working With Windows CE 4
- Configuration 5
- 5.1 Remote Desktop Connection
- 5.2 Pocket PC Compatibility
- 5.3 The Control Panel
- 5.4 Control Panel Icons
- 5.5 Basic Setup
- 5.7 Scanner Properties Setup
- 5.7.1 Scanner Options
- 5.7.2 Bar Codes
- 5.7.2.1 Code 39 Settings
- 5.7.2.2 Code 128 Settings
- 5.7.2.3 EAN 13 Settings
- 5.7.2.4 EAN 8
- 5.7.2.5 UPC And EAN Settings
- 5.7.2.6 UPC A Settings
- 5.7.2.7 UPC E Settings
- 5.7.2.8 Codabar
- 5.7.2.9 Code 93
- 5.7.2.10 Code 11
- 5.7.2.11 Interleaved 2 of 5
- 5.7.2.12 MSI Plessey
- 5.7.2.13 Discrete 2 of 5
- 5.7.2.14 IATA 2 of 5
- 5.7.2.15 Postal: Australian
- 5.7.2.16 Postal: Japanese
- 5.7.2.17 Postal: Korean
- 5.7.2.18 Postal: PlaNET
- 5.7.2.19 Postal: PostNET
- 5.7.2.20 Postal: Royal Mail
- 5.7.2.21 2D DataMatrix
- 5.7.2.22 2D Maxicode
- 5.7.2.23 2D PDF-417
- 5.7.2.24 2D Micro PDF-417
- 5.7.2.25 2D QR Code
- 5.7.2.26 2D RSS Code
- 5.7.2.27 Aztec
- 5.7.3 Translations
- 5.8 SNMP (Simple Network Management Protocol) Setup
- Tekterm Application 6
- 6.1 The Tekterm Application
- 6.2 Additional Keyboard Functions
- 6.3 Keyboard Modes
- 6.4 The Tekterm Status Area
- 6.5 TESS Emulation
- 6.6 ANSI Emulation
- 6.7 The Radio Statistics Screen
- 6.8 The Tekterm Startup Display Menu
- 6.9 Working With Menus
- 6.10 Resetting The 7535 Hand-Held Computer
- 6.11 The Parameters Menu
- 6.12 Display Options
- 6.13 More Parameters
- 6.14 Radio Parameters
- 6.15 System Parameters
- 6.16 Scanner Control Panel
- 6.17 View Manager
- 6.18 Applications
- 6.19 Ports- Tether And Console
- 6.20 Network
- Peripheral Devices & Accessories 7
- 7.1 External Bar Code Readers
- 7.2 The 7535 Battery
- 7.3 Important Charger Safety Instructions
- 7.4 Chargers
- 7.5 Gang Charger
- 7.6 Combo Charger
- 7.10 Bluetooth Peripherals
- 7.11 The 7535 Picker Cradle
- Specifications 8
- Support Services And Worldwide Offices
- Port Pinouts
- USB Setup Application

Chapter 6: Tekterm Application
Tether And Console Port Parameter Settings
238
Psion Teklogix 7535 Hand-Held Computer User Manual
Supports XON/XOFF or no handshaking.
Print: Used to output data only. All input characters except XON and
XOFF are ignored.
Supports XON/XOFF or no handshaking.
Output: Used to output data only. All input characters are ignored.
Supports no handshaking.
Note: To enable the input and/or output, ‘serial in’ and/or ‘serial out’ must be
enabled in the TESS menu.
Buffer
The value assigned to this parameter determines the size of the serial buffer used by
the application for both input and output. The buffer controls the amount of data the
application can send to or receive from a serial device.
Retries
This parameter determines the number of times the 7535 attempts to transmit a byte
from the serial port. If the count specified in this parameter is exceeded, the
transmission fails.
Input Tmo
This parameter sets the time in tenths of a second that the 7535 waits before passing
received data to the TESS or ANSI tasks.
Output Tmo
The value assigned at this parameter determines the maximum number of
milliseconds that the application will wait for a ‘write’ sent to the port to succeed
before it is aborted. The ‘write’ may be one or several bytes in length.
Test
When this parameter is enabled (set to “Y”), data is output through the serial port to
make certain that it is operating appropriately.