7.5.1 Installation
The gang charger can be wall mounted using the wall mount kit PN 1010039 or
it can be operated on a at surface. Install the charger in an area that is free from
excessive dirt, dust and contaminants. The ambient temperature must be in the range
0˚ C to 39˚ C (32˚ F to 102˚ F). The charger will not charge batteries outside
of this temperature range. For maximum performance, it is recommended that
the charger be operated at room temperature a temperature range between
18˚ C to 25˚ C (64˚ F to 77˚ F).
The charger can consume up to 2A @ 120VAC or 1A @ 240VAC. Check to ensure
the mains circuit supplying the charger is adequate for this loading (especially if
several chargers are being powered from the same circuit).
After unpacking the unit:
Visually check the charger for damage.
Install the IEC power cord and apply power.
A green indicator in the lower-right lights to indicate power is present. All charge
indicators ash momentarily at powerup to indicate that the charger is ready for
operation.
If you choose to wall mount the charger, follow the instructions packaged with the
mounting bracket kit. Be sure to locate the charger in an area where there is no risk
of injury to persons walking in the vicinity.
7.5.2 Operator Controls
The gang charger does not have operator controls or a power switch.