Appendix D: Teklogix Imagers Applet
Bar Code Symbologies – Descriptions
Codabar
D.4.10 Codabar
Enabled
Set this parameter to on to enable “Codabar”.
D.4.11 Interleaved 2 of 5
Enabled
Set this parameter to on to enable “Interleaved 2 of 5”.
Check Char
When this parameter is set to on, the integrity of a “Interleaved 2 of 5” symbol is checked to
ensure that it complies with specified algorithms.
Check Char Strip
If you enable this parameter, a check character is stripped from the decoded bar code data.
D.4.12 GS1 DataBar
GS1 DataBar
Set this parameter to on to enable the imager to read “GS1 Databar” symbols.
Minimum and Maximum Length
The length of a code refers to the number of characters (i.e., human readable characters), in-
cluding check digit(s). Double-tapping on these parameters displays a screen in which you
can set the minimum and maximum allowable code lengths – 4 to 74.
D.4.13 2D PDF-417
Enabled
Set this parameter to on to enable “2D PDF-417”.
D.4.14 2D Micro PDF-417
Enabled
Set this parameter to on to enable “2D Micro PDF-417”.