User's Manual

Table Of Contents
Chapter 5: Configuration
Options Tab
Psion Teklogix Omnii Hand-Held Computer User Manual 163
Multiple Beep Tones
You can set the audible scanner ‘beep’ to emit a series of three beeps instead of one. Set this
parameter to on to enable the multiple beep tones.
Good Scan Vibrates and Bad Scan Vibrates
These parameters determine whether or not Omnii creates a vibration when a good (success-
ful) scan or a bad (unsuccessful) scan is performed. Set these parameters to on to enable the
vibration. You can set the Number and Duration of vibrations, as well as the Pause between
vibrations. The screen above shows the default settings.
Soft Scan Timeout
This parameter is used by the SDK “Scan” function (soft-scan: starting a scan session via the
SDK function, instead of a physical user trigger press). The value assigned to this parameter
determines the soft-scan timeout from 1 to 10 sec (default is 3 sec).
Scan Log File
If this parameter is enabled, the input bar code and the modified/translated output bar code
are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if Scan Log File is enabled,
there is a slight performance reduction when performing multiple scans since the log file is
written to persistent storage.