User's Manual

Table Of Contents
Chapter 5: Configuration
Total Recall
Psion Teklogix Omnii Hand-Held Computer User Manual 169
Double-tapping on Trigger On Sequence or Trigger Off Sequence displays a screen with a
hex array of 10 elements.
These parameters work in conjunction with Manage Triggers sending on and off data
streams to the trigger module you assigned. For example, suppose you launch Manage Trig-
gers and choose Decoded Scanner as the ‘module to trigger’. Next, you assign a ‘trigger
key’—for this example, . (period). To define the serial stream of data bytes to control the on
and off function of the ‘trigger key’, enter a hex value in the Trigger On Sequence and the
Trigger Off Sequence fields. When you press the trigger key, the Trigger On Sequence is
sent and when you release the trigger key, the Trigger Off Sequence is sent, turning the
trigger key on and off.
5.13 Total Recall
Total Recall is a Psion Teklogix utility developed to maintain applications and settings
during a cold boot, and clone settings to other devices. This utility is based on a backup and
restore concept.
•In the Control Panel, choose the Total Recall icon.