User manual
C-8 Psion Teklogix Omnii XT10 Hand-Held Computer User Manual
Appendix C: Bar Code Settings
Decoded (Internal) Scanners
Decoded (Internal) Advanced Options
on this parameter, a dialog box is displayed in which you can enter a value of 0 msec, 200 
msec or 400 msec. A value of 0 (zero) disables the target dot.
Aim Duration 
This parameter determines the total time the aiming pattern appears before the scanner laser 
begins sweeping. When you double-tap on this parameter, a dialog box is displayed in which 
you can enter a value from 0 to 30 (0 to 3 sec.). A value of 0 (zero) disables the aiming-dot.
Laser On Time
The value assigned to this parameter determines how long the laser will remain on when the 
scan button or trigger is pressed.
Double-tapping on this parameter displays a dialog box in which you can enter a value 
between 5 and 99. The value is measured in tenths of seconds.
C.2.2 Decoded (Internal) Advanced Options
Continuous Scan Mode
Setting this parameter to on keeps the laser on and continuously decoding as long as the 
scanner button is pressed and held down.
Minimum Cancel Time
The value assigned to this parameter determines the time delay before the scanner is turned 
off, once the scanner trigger or button is released. This gives the scanner a minimum amount 
of time to complete its current decode before the scan is cancelled when you quickly trigger 
on/off.
Power Mode
This parameter is a power-saving option. Tapping on it displays a screen listing two power 
mode options: Continuous Power and Low Power.
In Continuous Power mode, the scanner is always on, waiting for a trigger pull or serial 
communication.
In Low Power mode, the scanner is in a standby state, drawing minimal power until a trigger 
pull or serial communication wakes it. Keep in mind that while this option is more suitable 
for battery powered applications, there will be a slight delay while the scanner powers up to 
scan a bar code.