User's Manual
Table Of Contents
- Cover
- TABLE OF CONTENTS
- Approvals & Safety Summary 1
- Introduction 2
- Basic Checkout 3
- Working With Windows CE 5.0 4
- Getting To Know The Warrington 5
- 5.1 Features Of The Warrington Hand-Held Computer
- 5.2 The Battery
- 5.3 Switching The Hand-Held On And Off
- 5.4 The Keyboard
- 5.5 The Display
- 5.6 Warrington Hand-Held Indicators
- 5.7 Monitoring The Battery And Maximizing Run Time
- 5.8 Uploading Data In A Docking Station
- 5.9 Bluetooth Radio
- 5.10 The MicroSD Card
- 5.11 General Maintenance
- Configuration 6
- 6.1 Remote Connect
- 6.2 The TekTerm Application
- 6.3 The Control Panel
- 6.4 Control Panel Icons
- 6.5 Basic Setup
- 6.6 Bluetooth Setup
- 6.7 Total Recall
- 6.8 The Storage Manager
- 6.9 IPv6 Support
- 6.10 Scanner Settings
- 6.10.1 Bar Codes
- 6.10.2 Decoded (Internal) Scanners
- 6.10.2.1 Options
- 6.10.2.2 Decoded (Internal) – Advanced Options
- 6.10.2.3 Decoded (Internal) – 2D Scanning Options
- 6.10.2.4 Decoded (Internal) Data Options
- 6.10.2.5 Code 39
- 6.10.2.6 Code 128
- 6.10.2.7 EAN 13
- 6.10.2.8 EAN 8
- 6.10.2.9 UPC A
- 6.10.2.10 UPC E
- 6.10.2.11 UPC/EAN Shared Settings
- 6.10.2.12 Code 93
- 6.10.2.13 Codabar
- 6.10.2.14 MSI Plessey
- 6.10.2.15 Interleaved 2 of 5
- 6.10.2.16 Discrete 2 of 5
- 6.10.2.17 RSS Code
- 6.10.2.18 Composite
- 6.10.2.19 PDF-417
- 6.10.2.20 Micro PDF-417
- 6.10.3 Decoded (ISCP)
- 6.10.3.1 Decoded (ISCP) – Options
- 6.10.3.2 Decoded (ISCP) – Advanced Options
- 6.10.3.3 Code 39
- 6.10.3.4 Code 128
- 6.10.3.5 EAN 13 Settings
- 6.10.3.6 EAN 8
- 6.10.3.7 UPC A
- 6.10.3.8 UPC E
- 6.10.3.9 UPC/EAN Shared Settings
- 6.10.3.10 Code 93
- 6.10.3.11 Codabar
- 6.10.3.12 MSI Plessey
- 6.10.3.13 Code 11
- 6.10.3.14 Interleaved 2 of 5
- 6.10.3.15 Matrix 2 of 5
- 6.10.3.16 Discrete 2 of 5
- 6.10.3.17 Telepen
- 6.10.3.18 RSS Code (Reduced Space Symbology)
- 6.10.3.19 PDF-417
- 6.10.3.20 Micro PDF-417
- 6.10.3.21 Codablock
- 6.10.4 Imager
- 6.10.4.1 Imager – Options
- 6.10.4.2 Imager – Advanced Options
- 6.10.4.3 Code 39 Settings
- 6.10.4.4 Code 128 Settings
- 6.10.4.5 EAN 13
- 6.10.4.6 EAN 8
- 6.10.4.7 UPC A
- 6.10.4.8 UPC E
- 6.10.4.9 Code 93
- 6.10.4.10 Codabar
- 6.10.4.11 Interleaved 2 of 5
- 6.10.4.12 RSS Code (Reduced Space Symbology)
- 6.10.4.13 Composite
- 6.10.4.14 PDF-417
- 6.10.4.15 Micro PDF-417
- 6.10.4.16 2D Data Matrix
- 6.10.4.17 2D QR Code
- 6.10.4.18 2D Maxicode
- 6.10.4.19 2D Aztec
- 6.10.4.20 Postal: PlaNET
- 6.10.4.21 Postal: PostNET
- 6.10.4.22 Postal: Australian
- 6.10.4.23 Postal: Japanese
- 6.10.4.24 Postal: Korean
- 6.10.4.25 Postal: Royal
- 6.10.5 Options
- 6.10.6 Translations Tab
- Peripheral Devices & Accessories 7
- 7.1 Carrying Accessories
- 7.2 The Battery
- 7.3 Adaptor Cable Options
- 7.4 Chargers And Docking Stations
- 7.5 Desktop Docking Station
- 7.7 Automotive Power Adaptor—Model #WA3113-G2
- 7.8 Quad Docking Station – PX3004
- 7.9 The Vehicle Cradle
- 7.10 Scanners And Imagers
- 7.11 Bluetooth Peripherals
- Specifications 8
- Port Pinouts
- Index
Chapter 6: Configuration
Code 128
156 Warrington Hand-Held Computer User Manual
GS1-128 Identifier
“GS1-128 Identifier” allows the AIM ID " ]C1" for EAN 128 to be transmitted or removed.
By default, this identifier is transmitted if EAN 128 is enabled.
GTIN Compliant
GTIN (global trade item number) processing transmits EAN 128 as the 14-character
EAN/UCC GTIN. To use GTIN processing, you must activate the EAN 128 symbology.
FNC1 Conversion
“FNC1 Conversion” allows the FNC1 character to be converted to another character for ap-
plications that cannot use the default <GS> Group Separator or hex (1d).
Double-tapping on this option displays a dialog box listing the allowable range: 0 to 255.
Enable ISBT 128
To successfully scan this type of bar code (International Society of Blood Transfusion), this
option must be set to on. If you enable this type of bar code, Code 128/EAN 128 is deacti-
vated to avoid any confusion.
ISBT Concat Transmit
The codes are not concatenated by default. You need to choose one of the options provided
for this parameter to send concatenated code. Choosing Only Concatenated Codes transmits
only concatenated codes—single codes will not be transmitted. Choosing Concatenated or
Single transmits single codes or concatenated codes. If only one code of a pair is read, that
code will be transmitted as a single code. If both codes in a pair are detected, they will be
concatenated provided that “ISBT Concat Any Pair” (see below) is enabled.
ISBT Concat Any Pair
Enabling this parameter causes all code pairs that can be, to be concatenated even if they do
not comply with Section 4.1 of the “ISBT 128 Bar Code Symbology and Application Speci-
fication for Labeling of Whole Blood and Blood Components” (June 2000, Version 1.2.1).
Reading Range
Determines the reading distance from which a bar code can be successfully scanned. The
default setting, Extended, allows for increased reading distance.
Important: When EAN 128 and GTIN processing are both activated, it is not possible
to read normal EAN 128 Codes.
Preliminary Draft