User's Manual
Teklogix 9150 Wireless Gateway User Manual 199
Chapter 7: 9100 Monitoring/Diagnostics
Diagnostics and Status Reporting
Figure 7.1 Annotated Console Information Screen
The possible states for any one port, as listed in Figure 7.1, are described below:
Disabled
Disabled in software via the console port. The port is inactive and will remain in
this state until it is enabled via the console, or the 9100 is reset. When the port is
activated, it transitions to the OFF state.
OFF
In this state the 9100 is constantly performing the auto-detect algorithm,
looking for 9150DCs connected to the port. When a 9150DC is found, the port
will transition to the ON state.
ON
A 9150DC has been found, and DC power is switched on. The port is constantly
monitored for fault conditions. If everything remains within operating specifica-
tion, the port will remain in the ON state. Fault conditions may transition the
port to the Low Current fault or High Current fault state.
9100 PowerBaseT – Build
1
: D161o
Main supply: Good
2
Port 1: Disabled current: 0 mA
Port 2: Off current: 0 mA
Port 3: On current
3
: 78 mA
Port 4: High Current
4
: current 0 mA
>
5
1
Firmware build date.
2
Could also read “Bad”.
3
Current consumed by an active port.
4
Possible states: Disabled
Off
On
Low Current
High Current
5
Input prompt.