Instruction manual

Page 8
Configuring the TM-1405GE Camera
TM-1405GE Software
3 Configuring the TM-1405GE Camera
The configuration of your GigE camera consists of two parts:
The imager configuration (CCD and control circuits)
The internal frame grabber configuration
The imager can be configured for partial scan, just like a Camera Link camera. The internal frame
grabber is automatically configured for the pixel type, windowing, image size and I/O and so on, by the
GigE camera software.
3.1 Setup
If you have a peer-to-peer connection between the TM-1405GE camera and your PC without network
switches, your packet size can be the default value (8128 bytes) as shown in Figure 9. However, if you
are connecting the TM-1405GE to your PC through a network switch, then you need to know maximum
packet size that your network switch supports. Typically, if your switch supports jumbo packets, then
you should keep the packet size to 8128 bytes. If your switch does not support jumbo packets, then you
may need to change the packet size to 1440 bytes.
Figure 9. Camera Interface Application Dialog Box
Note: If you connect the
camera through a network
switch, you may need to
modify the packet size.