Instruction manual
Page 15
Configuring the TM-1405GE Camera
TM-1405GE Software
3.4.7 Look-Up Table
The look-up table (LUT) control, shown in Section 20 on page 16, allows you to change two knee point 
values. 
Figure 20. Look-Up Table
Enter X
1
, Y
1
, X
2
, Y
2
 values directly to adjust the knee curve. In the integrated camera software, the 
look-up table cannot be controlled interactively. The Table Selection pull-down menu allows you to 
select the Linear or Gamma 45 option. This control also allows you to check the positive or negative 
image option.
3.4.8 Memory Pages
All the camera parameters such as shutter mode, shutter speed, gain, offset level, scan mode, and LUT 
can be saved into seven (7) available memory pages on the EEPROM in the camera. The pages are 
numbered 0-6. The Load Page button loads the corresponding camera settings from the EEPROM while 
the write page button writes the current camera settings to the corresponding memory page in the 
EEPROM.
Page 1, shown in Figure 21, is the power-up default page. Page 0 is the factory default. To save your 
current camera settings for power up default, write the settings to memory page 1. 
Figure 21. Memory Pages 
To reset memory page 1 to the factory default settings, load memory page 0 and save those settings to 
memory page 1. Page 0 is password-protected and you cannot write to it. If you find that you do need to 
write to page 0, contact JAI PULNiX for password access. 
Note: Configurations such as grabber settings, pulse generator, GPIO, and image setting must be saved 
into the XML file. Refer to Section 3.4.1, “Check the Current Camera Setting,” on page 12 for more 
information.