Instruction manual

Page 23
Signal Handling
TM-1405GE Software
4.5 Pulse Generators
The TM-1405GE camera has four independently programmable pulse generators. These generators can
run as either periodic or triggered. To run the pulse generators as triggered, they can be triggered on
either levels or signal edges. These generators can be tied to the camera inputs (camera-control lines).
For example, you can set pulse generator 0 in the Device Features tabbed dialog box to the following
values:
Delay = 600
Width = 14,000
Granularity = 1
Now check the Periodic option and change the camera settings to Async 9. This triggers the camera,
based on the pulse width set in the Pulse Generator page.
Be careful with the pulse generators GPIO input and output polarity. If the delay and pulse-width
duration are switched around, the output polarity must be negated in the GPIO lookup table.
The pulse generators are configured in the “Pulse Generator” section in the “Device Features” tab of the
Advanced Configuration window as shown in Figure 26.
Figure 26. Pulse Generator Page