Instruction manual

Page 24
GigE Series Camera Serial Commands
TM-1405GE Software
5 GigE Series Camera Serial Commands
You can control the GigE series cameras by serial command either using RS-232 or Camera Link. The
Start character is always “:” and the End character is always <CR> (return). For example, to set
Asynchronous Pulse Width Mode, send the command :ASH=9<CR> to the camera. Table 4 lists serial
commands you can use to control the camera.
Table 4. TM-1405GE Command List
Command Parameters
End of
Command
Ack
Response
Description
Gain, Vtop, Vbottom, and Vab
:MGA= XXX <cr> :o<cr> Set CDS gain (XXX = 047 - 0E7)
:VTP= XXX <cr> :o<cr> Set VTOP (XXX = 000 - 0FF)
:VBT= XXX <cr> :o<cr> Set VBOTTOM (XXX = 000 - 0FF)
Shutter Mode and Shutter Speed
:MSH= X <cr> :o<cr>
Set Manual Shutter (X = 0 manual, no
shutter)
:ASH= X <cr> :o<cr>
Set Async Shutter (X=0 async no shut-
ter, X=9 PWC)
:DSH= X <cr> :o<cr> Set Manual Direct Shutter (1-1052)
:ADS= XXX <cr> :0<cr>
Set Async Direct Shutter (DDD=000-
81F)
Data Output Control
:VDO S <cr> :o<cr> Video Data Output Order (s = A, B, C)
:DDP= N <cr> :o<cr>
Set output data depth
(N = 0 : 8 bit, N = 1 : 10 bit)
Auto Black Level Control
:EAOC XXX <cr> :o<cr>
Set Auto Black Level (XXX = H’000 -
H’OFF)
:DAOC Disable Auto Black Level