Datasheet

CP10.121, CP10.122
CP-Series
12V, 16A, 192W, SINGLE PHASE INPUT
4. DC-INPUT
Input voltage DC Nom. DC 110-150V ±20% For CP10.121
Nom. DC 110-300V ±20% For CP10.122
Input voltage range DC Min. 88-180Vdc For CP10.121
Min. 88-360Vdc For CP10.122
DC input current Typ. 1.90A At 110Vdc, 12V, 16A
Typ. 1.38A At 150Vdc, 12V, 16A
Typ. 0.68A At 300Vdc, 12V, 16A
Allowed voltage L/N to earth Max. 375Vdc Continuous, IEC 62477-1
Turn-on voltage Typ. 80Vdc Steady state value
Shut-down voltage Typ. 70Vdc Steady state value
typ. 55Vac Dynamic value (250ms)
Fig. 4-1 Wiring for DC Input
Instructions for DC use:
+
-
Load
L
PE
+
-
Power Supply
AC
DC
Battery
N
a) Use a battery or a similar DC source. A supply from the
intermediate DC-bus of a frequency converter is not
recommended and can cause a malfunction or damage
the unit.
b) Connect +pole to L and –pole to N.
c) Connect the PE terminal to an earth wire or to the
machine ground.
Aug. 2017 / Rev. 1.3 DS-CP10.121-EN
All parameters are typical values specified at 230Vac, 50Hz input voltage, 12V 16A output, 25°C ambient temperature and
after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
5/28