Datasheet

CP10.121, CP10.122
CP-Series
12V, 16A, 192W, SINGLE PHASE INPUT
6. OUTPUT
Output voltage Nom. 12Vdc
Adjustment range Min. 12-15Vdc Guaranteed value
Max. 16.5Vdc This is the maximum output voltage which can occur
at the clockwise end position of the potentiometer
due to tolerances. It is not a guaranteed value which
can be achieved.
Factory settings Typ. 12.0Vdc ±0.2% At full load and cold unit
Line regulation Max. 10mV Between 85 and 300Vac
Load regulation Max. 50mV Between 0 and 19.2A, static value, see Fig. 6-1
Ripple and noise voltage Max. 50mVpp Bandwidth 20Hz to 20MHz, 50Ohm
Output current Nom. 19.2A
1)
At 12V and an ambient temperature below 45°C,
see Fig. 17-1
Nom. 16A At 12V and 60°C ambient temperature, see Fig. 6-1
Nom. 12A At 12V and 70°C ambient temperature, see Fig. 17-1
Nom. 15.4A
1)
At 15V and an ambient temperature below 45°C,
see Fig. 17-1
Nom. 12.8A At 15V and 60°C ambient temperature, see Fig. 6-1
Nom. 9.6A At 15V and 70°C ambient temperature, see Fig. 17-1
Typ. 48A For minimal 12ms once every five seconds, see Fig. 6-2.
The output voltage stays above 10V. See chapter 25.1
for more peak current measurements. For AC 100V
mains, the pulse length is shorter than 12ms.
Output voltage above 6.5Vdc, see Fig. 6-1Overload behaviour Continuous current
Hiccup
PLUS
mode
2)
Output voltage below 6.5Vdc, see Fig. 6-1
Short-circuit current Min. 20.5A
3)
Load impedance <30mOhm, see Fig. 6-3
Max. 25.5A
3)
Load impedance <30mOhm, see Fig. 6-3
Max. 7.3A Average (R.M.S.) current, load impedance 50mOhm,
see Fig. 6-3
Min. 50A Up to 12ms, load impedance <30mOhm, see Fig. 6-2
Typ. 55A Up to 12ms, load impedance <30mOhm, see Fig. 6-2
Output capacitance Typ. 5 350μF Included inside the power supply
1) Power Boost
This power/ current is continuously allowed up to an ambient temperature of 45°C.
Above 45°C, do not use this power/ current longer than a duty cycle of 10% and/ or not longer than 1 minute every 10 minutes.
2) Hiccup
PLUS
Mode
At heavy overloads (when output voltage falls below 6.5V), the power supply delivers continuous output current for 2s. After this, the
output is switched off for approx. 18s before a new start attempt is automatically performed. This cycle is repeated as long as the overload
exists. If the overload has been cleared, the device will operate normally. See Fig. 6-3
3) Discharge current of output capacitors is not included.
Aug. 2017 / Rev. 1.3 DS-CP10.121-EN
All parameters are typical values specified at 230Vac, 50Hz input voltage, 12V 16A output, 25°C ambient temperature and
after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
7/28