Datasheet
CP10.121
CP-Series
12V, 16A, SINGLE PHASE INPUT
11. LIFETIME EXPECTANCY AND MTBF
AC 100V AC 120V AC 230V
Lifetime expectancy
*)
153 000h 170 000h 189 000h at 12V, 8A and 40°C
434 000h 482 000h 534 000h at 12V, 8A and 25°C
57 000h 65 000h 83 000h at 12V, 16A and 40°C
162 000h 184 000h 234 000h at 12V, 16A and 25°C
26 000h 31 000h 45 000h at 12V, 19.2A and 40°C
74 000h 88 000h 127 000h at 12V, 19.2A and 25°C
MTBF
**)
SN 29500, IEC 61709 T.B.D. T.B.D. T.B.D. at 12V, 16A and 40°C
T.B.D. T.B.D. T.B.D. at 12V, 16A and 25°C
MTBF
**)
MIL HDBK 217F T.B.D. T.B.D. T.B.D. at 12V, 16A and 40°C;
Ground Benign GB40
T.B.D. T.B.D. T.B.D. at 12V, 16A and 25°C;
Ground Benign GB25
T.B.D. T.B.D. T.B.D. at 12V, 16A and 40°C;
Ground Fixed GF40
T.B.D. T.B.D. T.B.D. at 12V, 16A and 25°C;
Ground Fixed GF25
*) The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by the lifetime
expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and is calculated according to the
capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors only guarantees a maximum life of up to 15 years
(131 400h). Any number exceeding this value is a calculated theoretical lifetime which can be used to compare devices.
**) MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates reliability of a
device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily represent the life of a product.
The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h means that
statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it cannot be determined if the failed unit
has been running for 50 000h or only for 100h.
12. FUNCTIONAL DIAGRAM
Fig. 12-1 Functional diagram
+
+
-
-
Output
Over-
Voltage
Protection
PFC
Converter
Output
Voltage
Regulator
Power
Converter
Output
Filter
Output
Power
Manager
Temper-
ature
Shut-
down
Input Fuse
Input Filter
Input Rectifier
Inrush Current Limiter
V
OUT
L
N
DC-ok
Contact
DC-ok
LED
DC-ok
Relay
-
Remote
13
ON / OFF
(Shut-down)
14
ON/
OFF
15
16
Jun. 2015 / Rev. 1.0 DS-CP10.121-EN
All parameters are specified at 12V, 16A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
10/26