14. FRONT SIDE AND USER ELEMENTS
Fig. 14-1
Front side
A
Input Terminals (screw terminal)
N, L Line input
PE (Protective Earth) input
B
Output Terminals (screw terminal, two identical + poles and three identical - poles)
+ Positive output
Negative (return) output
C Output voltage potentiometer
Open the flap to adjust the output voltage. Factory set: 12.0V
D DC-OK LED (green)
On, when the output voltage is >90% of the adjusted output voltage
E
DC-OK Relay Contact (quick-connect spring-clamp terminals)
Monitors the output voltage of the running power supply.
See chapter 8 for details.
F Shut-down Input (quick-connect spring-clamp terminals)
Pin 15 and 16 must be connected to turn the power supply off.
See chapter 9 for details.
Jun. 2015 / Rev. 1.0 DS-CP10.121-EN
All parameters are specified at 12V, 16A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany
12/26