Datasheet
CP10.121
CP-Series
12V, 16A, SINGLE PHASE INPUT
Switching Frequencies
The power supply has two converters with two different switching frequencies included.
Switching frequency 1 110kHz PFC converter, input voltage and output power dependent
Switching frequency 2 110kHz to 140kHz Main converter, output power dependent
16. ENVIRONMENT
Operational temperature
*)
-25°C to +70°C (-13°F to 158°F) reduce output power according Fig. 16-1
Storage temperature -40°C to +85°C (-40°F to 185°F) for storage and transportation
Output de-rating 2.5W/°C
4.8W/°C
45°C to 60°C (113°F to 140°F)
60°C to 70°C (140°F to 158°F)
Humidity
**)
5 to 95% r.h. IEC 60068-2-30
Vibration sinusoidal 2-17.8Hz: ±1.6mm; 17.8-500Hz: 2g
***)
2 hours / axis
***)
IEC 60068-2-6
Shock 30g 6ms, 20g 11ms
***)
3 bumps / direction, 18 bumps in total
IEC 60068-2-27
Altitude 0 to 2000m (0 to 6 560ft) without any restrictions
2000 to 6000m (6 560 to 20 000ft) reduce output power or ambient temperature,
see Fig. 16-2.
IEC 62103, EN 50178, overvoltage category II
Altitude de-rating 13.5W/1000m or 5°C/1000m > 2000m (6500ft), see Fig. 16-2
Over-voltage category III IEC 62103, EN 50178, altitudes up to 2000m
II altitudes from 2000m to 6000m
Degree of pollution 2 IEC 62103, EN 50178, not conductive
LABS compatibility The unit does not release any silicone or other LABS-critical substances and is suitable for
use in paint shops.
*) Operational temperature is the same as the ambient or surrounding temperature and is defined as the air temperature 2cm below the
unit.
**) Do not energize while condensation is present
***) Tested in combination with DIN-Rails according to EN 60715 with a height of 15mm and a thickness of 1.3mm and standard
orientation.
Fig. 16-1 Output current vs. ambient temp. Fig. 16-2 Output current vs. altitude
Allowed Output Current at 12V
0
14/26
-25 0 20 40
70°C
4A
8A
12A
16A
20A
60
A
A... 85 to 264Vac, continuous
B... short term
B
0
0 2000m 4000m
6000m
4A
8A
12A
16A
20A
Allowed Output Current at 12V
Ambient Temperature
Altitude
B
C
A
.
.
.
T
a
m
b
<
6
0
°
C
B
.
.
.
T
a
m
b
<
5
0
°
C
C
.
.
.
T
a
m
b
<
4
0
°
C
D
.
.
.
S
h
o
r
t
t
e
r
m
A
D
Jun. 2015 / Rev. 1.0 DS-CP10.121-EN
All parameters are specified at 12V, 16A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany