9. EFFICIENCY AND POWER LOSSES
AC 100V AC 120V AC 230V
Efficiency Typ. 93.1% 93.8% 95.4% At 36V, 6.7A
Typ. 92.8% 93.6% 95.3% At 36V, 8A (Power Boost)
Average efficiency
*)
Typ. 92.4% 93.1% 94.3% 25% at 1.7A, 25% at 3.4A,
25% at 5A. 25% at 6.7A
Power losses Typ. 2.4W 2.2W 1.8W At 36V, 0A
Typ. 9.5W 8.3W 7.0W At 36V, 3.35A
Typ. 17.8W 15.9W 11.6W At 36V, 6.7A
Typ. 22.3W 19.7W 14.2W At 36V, 8A (Power Boost)
*) The average efficiency is an assumption for a typical application where the power supply is loaded with 25% of the nominal load for 25%
of the time, 50% of the nominal load for another 25% of the time, 75% of the nominal load for another 25% of the time and with 100%
of the nominal load for the rest of the time.
Fig. 9-1 Efficiency vs. output current at 36V,
typ.
Fig. 9-2 Losses vs. output current at 36V, typ.
Efficiency
23456
7
8A
90
91
92
93
94
95
96%
Output Current
(
a
)
(
b
)
(
c
)
(a) 100Vac
(b) 120Vac
(c) 230Vac
Power Losses
012 4 8A
5
0
10
15
20
30W
6
25
35
Output Current
7
(
a
)
(
b
)
(
c
)
(a) 100Vac
(b) 120Vac
(c) 230Vac
Fig. 9-3 Efficiency vs. input voltage at 36V,
6.7A, typ.
Fig. 9-4 Losses vs. input voltage at 36V, 6.7A,
typ.
Efficiency
10/29
120 180 230 264Vac
90
91
92
93
Input Voltage
94
95
96%
100
Power Losses
120 180 230 264Vac
10
12
14
16
Input Voltage
18
20
22W
100
Aug. 2017 / Rev. 1.1 DS-CP10.361-EN
All parameters are specified at 36V, 6.7A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.