10. LIFETIME EXPECTANCY
The Lifetime expectancy shown in the table indicates the minimum operating hours (service life) and is determined by
the lifetime expectancy of the built-in electrolytic capacitors. Lifetime expectancy is specified in operational hours and
is calculated according to the capacitor’s manufacturer specification. The manufacturer of the electrolytic capacitors
only guarantees a maximum life of up to 15 years (131 400h). Any number exceeding this value is a calculated
theoretical lifetime which can be used to compare devices.
AC 100V AC 120V AC 230V
Lifetime expectancy 150 000h 163 000h 196 000h At 36V, 3.35A and 40°C
75 000h 87 000h 130 000h At 36V, 6.7A and 40°C
54 000h 68 000h 112 000h At 36V, 8A and 40°C
425 000h 462 000h 553 000h At 36V, 3.35A and 25°C
211 000h 246 000h 368 000h At 36V, 6.7A and 25°C
152 000h 192 000h 316 000h At 36V, 8A and 25°C
11. MTBF
MTBF stands for Mean Time Between Failure, which is calculated according to statistical device failures, and indicates
reliability of a device. It is the statistical representation of the likelihood of a unit to fail and does not necessarily
represent the life of a product.
The MTBF figure is a statistical representation of the likelihood of a device to fail. A MTBF figure of e.g. 1 000 000h
means that statistically one unit will fail every 100 hours if 10 000 units are installed in the field. However, it cannot be
determined if the failed unit has been running for 50 000h or only for 100h.
AC 100V AC 120V AC 230V
MTBF SN 29500, IEC 61709 550 000h 560 000h 661 000h At 36V, 6.7A and 40°C
1 003 000h 1 017 000h 1 176 000h At 36V, 6.7A and 25°C
MTBF MIL HDBK 217F 188 000h 188 000h 213 000h At 36V, 6.7A and 40°C;
Ground Benign GB40
252 000h 252 000h 290 000h At 36V, 6.7A and 25°C;
Ground Benign GB25
40 000h 40 000h 47 000h At 36V, 6.7A and 40°C;
Ground Fixed GF40
51 000h 51 000h 61 000h At 36V, 6.7A and 25°C;
Ground Fixed GF25
Aug. 2017 / Rev. 1.1 DS-CP10.361-EN