Datasheet

CP10.361
CP-Series
36V, 6.7A, 240W, SINGLE PHASE INPUT
3. AC-INPUT
AC input Nom. AC 100-240V Suitable for TN-, TT- and IT mains networks
AC input range Min. 85-264Vac Continuous operation
Min. 264-300Vac For maximal 500ms
Allowed voltage L or N to earth Max. 300Vac Continuous according to IEC 62477-1
Input frequency Nom. 50–60Hz ±6%
Turn-on voltage Typ. 80Vac Steady-state value, see Fig. 3-1
Shut-down voltage Typ. 70Vac Steady-state value, see Fig. 3-1
Typ. 55Vac Dynamic value for maximal 250ms
External input protection See recommendations in chapter 24.3.
AC 100V AC 120V AC 230V
Input current Typ. 2.62A 2.16A 1.13A At 36V, 6.7A, see Fig. 3-3
Power factor
*)
Typ. 0.99 0.99 0.97 At 36V, 6.7A, see Fig. 3-4
Crest factor
**)
Typ. 1.5 1.5 1.65 At 36V, 6.7A
Start-up delay Typ. 300ms 290ms 240ms See Fig. 3-2
Rise time Typ. 60ms 60ms 60ms At 36V, 6.7A const. current load,
0mF load capacitance, see Fig. 3-2
Typ. 120ms 120ms 120ms At 36V, 6.7A const. current load,
7mF load capacitance,, see Fig. 3-2
Turn-on overshoot Max. 200mV 200mV 200mV See Fig. 3-2
External input protection See recommendations in chapter 24.3.
*) The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.
**) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform.
Fig. 3-1 Input voltage range Fig. 3-2 Turn-on behavior, definitions
Turn-on
85V
Rated
input range
max.
500ms
V
IN
P
OUT
4/29
300Vac264V
Shut-down
Start-up Rise
delay Time
Overshoot
- 5%
Output
Voltage
Input
Voltage
Fig. 3-3 Input current vs. output current at
36V output voltage
Fig. 3-4 Power factor vs. output current at
36V output voltage
8A
1
24356
0
0.5
1.0
1.5
2.0
2.5
3A
Input Current, typ.
7
a) 100Vac
b) 120Vac
c) 230Vac
Output Current
(a)
(b)
(c)
Power Factor, typ.
123456 8A
0.75
0.8
0.85
0.9
0.95
1.0
7
Output Current
(a) 100Vac,
(b) 120Vac,
(c) 230Vac
(a)
(b)
(c)
Aug. 2017 / Rev. 1.1 DS-CP10.361-EN
All parameters are specified at 36V, 6.7A, 230Vac, 50Hz, 25°C ambient and after a 5 minutes run-in time unless otherwise noted.
www.pulspower.com Phone +49 89 9278 0 Germany